User's Manual Part 2
Tech-X Flex User Guide - Firmware v06.50 Tech-X Flex
®
(NG2)
6-12
Intro
Overview
Wi-Fi
Ethernet
System
IP/Video
MoCA
RF
Specs
6.7.1 Setup - Single Device PLT
The setup requires only the Destination for the ping tests:
Figure 6-7 Single Device PLT - Setup
CAUTION: You should select the destination for this test carefully. Because it effectively
sends a continuous stream of packets to a single host, it could be construed as
a denial-of-service attack by a third party that does not welcome such traffic.
6.7.2 Results - Single Device PLT
The test runs indefinitely until manually stopped. Results are reported at approximately 1-second
intervals and are as follows:
Table 6-9 Single Device PLT results
Measurement Description
# Sent Total number of ping requests sent since the beginning of the test.
# Recv The total number of ping requests that successfully received a reply, as of the end of
the respective reporting interval.
Preliminary issue - Limited distribution only!