User's Manual Part 2
Tech-X Flex
®
(NG2) Tech-X Flex User Guide - Firmware v06.50
8-13
Intro
Overview
Wi-Fi
Ethernet
System
IP/Video
MoCA
RF
Specs
NOTE: Any individual result that appears in red (including a bar graph) has violated a threshold
configured for the unit. For more information on configuring thresholds, see Thresholds on
page 8-23.
PASS/FAIL status
If any measurement for a channel violates the respective configured threshold, the channel is reported
as FAIL. For the Channel Sweep Test specifically, note that the PASS/FAIL indication refers to the
selected channel only.
For more information on configuring thresholds, see Thresholds on page 8-23.
Bar graph and power measurement notes
Bar graphs are provided for a simple graphical representation of certain measurements, such as power
levels. RF testing includes two basic types of bar graphs.
The first type uses a chart format, with the currently-active thresholds shown as shaded areas. For
example, the following graph shows a power measurement of -1.30 dBmV, slightly below the lower
threshold of 0.0 dBmV and therefore shown as a violation:
Figure 8-9 Bar graph notations
Other important notes about this type of bar graph include:
Lower threshold
(0 dBmV)
Upper threshold
(15 dBmV)
Preliminary issue - Limited distribution only!