User's Manual

SmartCloud Radio Node - SCRN 200 Hardware Installation Guide
SpiderCloud Wireless, Inc.
12
Installation and Mount Bracket Assembly
The radio node has a pedestal base that slides into a long “U” shaped bracket for ceiling or wall mounting.
SpiderCloud pre-bolts the pedestal base onto the extrusion plate on the radio node. However you must
attach the pedestal base to the mount bracket as shown in Figure 8:
Figure 8 Pedestal Base Slides into Mount Bracket
Bracket Mounting and Cabling Guidelines
Incorrectly cabling and mounting a radio node can result in crushed cables and loss of communications to
the unit. Follow these guidelines in cabling the radio node and mounting it on the bracket:
Ensure that the cabling is properly routed and dressed.
Ensure that the pedestal base is fully inserted into the mount bracket so that it locks into place
and is flush. A correctly installed cable should at no time during installation impede inserting
the pedestal base into the mount bracket.
Secure the pedestal base to the mount bracket with a padlock or tie wrap to provide physical
security.
Installation Procedure
The radio node receives its power source over powered Ethernet. If your wiring closet does not have
existing PoE+ equipment, SpiderCloud recommends a PoE+ power injector for the radio node. See
section PoE+ on page 9.
Mount Bracket Pedestal Base