User's Manual

36
3 Function description
3.1 Function of the access control system
The access control system consists of the WT 210 wall terminal with an external power supply, a connected
electric or electro-mechanic opening device like anelectric strike, and the configuration software.
The settings of the WT 210, which are made in the configuration software, are transmitted to the WT 210
using the MDU 110 mobile data transfer unit.
Audit trails are also read out from the WT 210 using the MDU 110 so that they can be loaded into the software
of the administrator's PC and processed.
Other components such as a door strike pushbutton can also be connected to the WT 210.
Among others, the following configuration examples are possible:
One door with a WT 210, electric door strike and pushbutton on the inside
Chapter 3.4.1 Installation version 1: Door with WT 210, electric strike on page 37
A door with a WT 210, electric door strike and protection against tampering
Chapter 3.4.2 Installation version 2: Door with WT 210, electric strike and sabotage protection
on page 38
3.2 WT 210 pin assignments
Connection
Use
+12V, GND
Power supply 12 VDC 24 VDC
A, B
RS 485
ALARM
Alarm output, NC
IN+, IN-
Gate input, 5 24V, 20mA max.
NC, NO, COM
Relay output, changeover contact
+12V IN+
GND IN-
B GND
A COM
ALARM NO
ALARM NC
+12V IN+
GND IN-
B GND
A COM
ALARM NO
ALARM NC