SAFETY DATA SHEET
XIAMETER(R) SLT-7001 SEALANT OXIME
CLEAR-M
Version
3.0
Revision Date:
04/25/2016
SDS Number:
702926-00005
Date of last issue: 10/01/2015
Date of first issue: 11/03/2014
13 / 19
N-(3-(Trimethoxysilyl)propyl)ethylenediamine:
Routes of exposure: Ingestion
Assessment:
No significant health effects observed in animals at concentrations of 100 mg/kg
bw or less.
Methyltri(ethylmethylketoxime)silane isomers and oligomers:
Routes of exposure: Ingestion
Target Organs:
Blood
Assessment:
Shown to produce significant health effects in animals at concentrations of >10 to
100 mg/kg bw.
Repeated dose toxicity
Ingredients:
Methyltri(ethylmethylketoxime)silane:
Species: Rat
Application Route:
Ingestion
Target Organs:
Blood
Remarks:
Based on test data
Vinyltri (methylethylketoxime) silane:
Species: Rat
Application Route:
Ingestion
Target Organs:
Blood
Remarks:
Based on data from similar materials
N-(3-(Trimethoxysilyl)propyl)ethylenediamine:
Application Route: Ingestion
Remarks:
Based on test data
Methyltri(ethylmethylketoxime)silane isomers and oligomers:
Species: Rat
Application Route:
Ingestion
Target Organs:
Blood
Remarks:
Based on data from similar materials
Aspiration toxicity
Not classified based on available information.
Further information
Product:
Remarks: During use of the material, small amounts of methylethylketoxime (MEKO) will be re-
leased. Rodents exposed to chronic MEKO inhalation throughout their lifetimes showed signifi-
cant increases in liver tumor rates.