GLASS BLOCK SILICONE Packaged & Made by TBP Converting, Inc.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 SECTION 1.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 P302 + P352 IF ON SKIN: Wash with plenty of soap and water. P314 Get medical advice/ attention if you feel unwell. P333 + P313 If skin irritation or rash occurs: Get medical advice/ attention. P363 Wash contaminated clothing before reuse.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 Most important symptoms and effects, both acute and delayed : May cause an allergic skin reaction. May cause damage to organs through prolonged or repeated exposure if swallowed.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 containment and cleaning up Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 For large spills, provide diking or other appropriate containment to keep material from spreading. If diked material can be pumped, store recovered material in appropriate container. Clean up remaining materials from spill with suitable absorbent.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 Hazardous components without workplace control parameters Ingredients Methyltri(ethylmethylketoxime) silane Vinyltri (methylethylketoxime) silane N-(3(Trimethoxysilyl)propyl)ethylen ediamine Methyltri(ethylmethylketoxime) silane isomers and oligomers CAS-No.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 resistance data and an assessment of the local exposure potential. Skin contact must be avoided by using impervious protective clothing (gloves, aprons, boots, etc). Hygiene measures : Ensure that eye flushing systems and safety showers are located close to the working place. When using do not eat, drink or smoke.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 Decomposition temperature : No data available Viscosity Viscosity, dynamic : Not applicable Explosive properties : Not explosive Oxidizing properties : The substance or mixture is not classified as oxidizing. Molecular weight : No data available SECTION 10.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 Skin corrosion/irritation Not classified based on available information. Ingredients: Silicon dioxide: Result: No skin irritation Remarks: Information taken from reference works and the literature.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 Assessment: The substance or mixture has no acute oral toxicity Remarks: Information taken from reference works and the literature. Acute inhalation toxicity : LC50 (Rat): > 2.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 Respiratory or skin sensitization Skin sensitization May cause an allergic skin reaction. Respiratory sensitization Not classified based on available information. Ingredients: Silicon dioxide: Assessment: Does not cause skin sensitization.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 Genotoxicity in vitro : Result: negative Remarks: Information taken from reference works and the literature. Genotoxicity in vivo : Application Route: Ingestion Result: negative Remarks: Information taken from reference works and the literature.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 Effects on fertility : Test Type: Combined repeated dose toxicity study with the reproduction/developmental toxicity screening test Species: Rat, male and female Application Route: Ingestion Symptoms: No effects on fertility.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 N-(3-(Trimethoxysilyl)propyl)ethylenediamine: Routes of exposure: Ingestion Assessment: No significant health effects observed in animals at concentrations of 100 mg/kg bw or less.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 SECTION 12.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 Toxicity to daphnia and other : aquatic invertebrates (Chronic toxicity) NOEC (Daphnia sp.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 Other adverse effects No data available SECTION 13. DISPOSAL CONSIDERATIONS Disposal methods Resource Conservation and Recovery Act (RCRA) : This product has been evaluated for RCRA characteristics and does not meet the criteria of hazardous waste if discarded in its purchased form.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 *: Calculated RQ exceeds reasonably attainable upper limit. SARA 311/312 Hazards : Acute Health Hazard Chronic Health Hazard SARA 302 : No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.0 Revision Date: 04/25/2016 SDS Number: 702926-00005 Date of last issue: 10/01/2015 Date of first issue: 11/03/2014 SECTION 16. OTHER INFORMATION Further information NFPA: 2 0 Instability 1 Health HMIS III: Flammability HEALTH 2* FLAMMABILITY 1 PHYSICAL HAZARD 0 0 = not significant, 1 =Slight, 2 = Moderate, 3 = High 4 = Extreme, * = Chronic Special hazard. Full text of other abbreviations NIOSH REL : USA.
SAFETY DATA SHEET XIAMETER(R) SLT-7001 SEALANT OXIME CLEAR-M Version 3.