User Guide
© 2018 All Rights Reserved.
7
General Maintenance
and Storage
Troubleshooting
PROBLEM PROBABLE CAUSE SOLUTION
Motor does not start • Switch not on
• No power
• Bad connection
• Internal pump pressure
switch senses high pressure
• Failed switch
• Failed motor/pump
• Blown fuse
• Turn switch on
• Check for power at outlet
• Check for loose wire connections
• Ensure output of pump is
not blocked
• Replace
• Replace
• Replace
Water does not circulate
• Pump not working
• Liquid level too low
• Replace pump head or clean
and repair
• Make sure liquid level is above
inlet hose strainer in bucket
while circulating
Liquid spewing from unit • Too much descaling solution • Stop adding acid.
• Remove some liquid, neutralize
and discard according local
regulations
SC-DS-05
Pump Type Diphragm
Motor 1/6 HP, 115v. 1 Amps 50/60 Hz
(1/6 HP, 220 V, 0.6 Amps, 50/60 Hz)
Maximum Flow 3 GPM [11 Lpm]
Maximum Head 69 Feet
Motor Rating Intermittent
Temperature Range 0° F to 130° F+ (54°C)
Dimensions Height 19”, Diameter 14”, Weight: 11 lbs
[with bucket]
Capacity 4 gal [15 L]
Hose Threaded Connections Female Garden Hose
Technical Data