20 Pound Capacity 170 Pound Capacity Refer to page 3 for Model Identification TMB1268C TMB1268C Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) Part No.
Installation/Operation Supplement Installation must conform with local codes. WARNING WARNING FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death. W033 • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. • WHAT TO DO IF YOU SMELL GAS: – Do not try to light any appliance.
Installation/Operation Supplement Table of Contents Introduction......................................................................................... Model Identification ............................................................................. Wiring Diagram Location..................................................................... Serial Plate Location............................................................................. 3 3 3 4 Safety Information.....................................
Installation/Operation Supplement Introduction Model Identification Information in this manual is applicable to these models.
Installation/Operation Supplement Serial Plate Location 1 120 POUND TUMBLER 1 170 POUND TUMBLER TMB1298N TMB1298N 1 4 Serial Plate © Published by permission of the copyright owner – DO NOT COPY or TRANSMIT M414881 (EN)
Installation/Operation Supplement Safety Information Save These Instructions Important Safety Instructions 13. Keep area around the exhaust opening and adjacent surrounding area free from the accumulation of lint, dust and dirt. WARNING Hazardous Voltage. Can cause shock, burn or cause death. Allow machine power to remain off for two minutes prior to working in and around AC inverter drive. W359 1. Read all instructions before using the tumbler. 2.
Installation/Operation Supplement 22. Install this tumbler according to the INSTALLATION INSTRUCTIONS. All connections for electrical power, grounding, and gas supply must comply with local codes and be made by licensed personnel when required. 23. Remove laundry immediately after tumbler stops. 24. Always read and follow manufacturer’s instructions on packages of laundry and cleaning aids. Heed all warnings or precautions.
Installation/Operation Supplement Installation Specifications and Dimensions Specifications 120 Pound 170 Pound 66 dBA 66 dBA 1118 x 1041 (44 x 41) 1289 x 1080 (50.75 x 42.5) Cylinder Capacity dry weight: kg (lbs.) 54.4 (120) 77.1 (170) Cylinder Motor Horsepower 0.75 0.75 1 3 Air Outlet Diameter: mm (in.) 254 (10) 300 (12) Maximum Static Back Pressure: mbar (inches W.C.) 0.8 (0.3) 0.8 (0.3) 755 (1600) 1156 (2450) 580 (1275) 716 (1575) 3/4 in. NPT 1 in.
Installation/Operation Supplement 120 Pound Tumbler Dimensions and Exhaust Outlet Locations TOP VIEW OF EXHAUST DUCT X W X V H U B A Y Z C F D E G TMB2211N TMB2211N Cabinet Dimensions Models A B C D E F G H 120L/N 797 mm (31.38 in.) 826 mm (32.5 in.) 1242 mm (48.91 in.) 1268 mm (49.91 in.) 1725 mm (67.92 in.) 1153 mm (45.38 in.) 1178 mm (46.38 in.) 2177 mm (85.7 in.) 120S 797 mm (31.38 in.) 826 mm (32.5 in.) 1242 mm (48.91 in.) 1268 mm (49.91 in.) 1725 mm (67.92 in.
Installation/Operation Supplement 170 Pound Tumbler Dimensions and Exhaust Outlet Locations TOP VIEW OF EXHAUST DUCT Y X W Y H B V A C F D E G TMB2212N TMB2212N Cabinet Dimensions Models A B C D E F G H 170L/N/S 860 mm (33.86 in.) 826 mm (32.5 in.) 1289 mm (50.75 in.) 1314 mm (51.75 in.) 1749 mm (68.85 in.) 1324 mm (52.12 in.) 1349 mm (53.12 in.) 2388 mm (94 in.) Refer to Position and Level the Tumbler to temporarily reduce the heights of these models.
Installation/Operation Supplement Electric and Gas Connection Locations for Gas Models C A A C B B D D 120L/N 170L/N TMB1301N Electrical Connection Gas Connection Models A B C D Diameter 120L/N 500 mm (19.69 in.) 1904 mm (74.98 in.) 325 mm (12.78 in.) 1781 mm (70.12 in.) 3/4 in. NPT 170L/N 589 mm (23.18 in.) 2003 mm (78.85 in.) 368 mm (14.5 in.) 1965 mm (77.38 in.) 1 in. NPT NOTE: These figures are approximate dimensions only.
Installation/Operation Supplement Electric and Steam Connection Locations for Steam Models A1 A2 A1 A2 C C B2 B1 B2 B1 D E F E D 120S F 170S TMB1461N fdf Models 120S 170S Steam Inlet Diameter A1 A2 F 3/4 in. NPT 911 mm (35.875 in.) 340 mm (13.375 in.) 2102 mm (82.75 in.) 3/4 in. NPT 956 mm (37.625 in.) 387 mm (15.25 in.) 2235 mm (88 in.) Steam Outlet 120S 170S Diameter B1 B2 D 3/4 in. NPT 879 mm (34.625 in.) 333 mm (13.125 in.) 1740 mm (68.5 in.) 1 in. NPT 1133 mm (44.
Installation/Operation Supplement Position and Level the Tumbler WARNING To reduce the risk of severe injury, clearance of tumbler cabinet from combustible construction must conform to the minimum clearances. W056 1 3 2 4 5 6 7 TMB2020N 8 TMB2020N NOTE: Shaded areas indicate adjacent structure. 1 13 mm (0.5 in.) recommended between machines for removal or installation. 2 Allow 51-102 mm (2-4 in.) opening at top of machine to aid in removal or installation.
Installation/Operation Supplement Fire Suppression System Water Connections G, H, K, S and U Models Only 1 Water Requirements IMPORTANT: Water must be supplied to the fire suppression system, or the fire suppression system will not operate as intended. Connection point to the electric water solenoid valve is a 19 mm (3/4 inch) hose.
Installation/Operation Supplement Auxiliary Alarm During tumbler installation, you have the option to connect a separate alarm system to this auxiliary output. Use of the auxiliary output is not required for the fire suppression system to operate, but may be used for additional protection. NOTE: The auxiliary output is activated during fire suppression system maintenance test sequence. Consider this fact prior to your system test every three months.
Installation/Operation Supplement Serial plates supplied from the factory are configured for the countries of GB/IE/PT/ES/IT/GR/LU/CH. These instructions pertain to the situations when the country of use or gas supply is different than that on the serial plate. NOTE: This manual is only a supplement. Refer to installation/operation manual for full instructions.
Installation/Operation Supplement Gases and Configurations Country Code DK/NO/ SE/FI/CZ/ EE/LV/LT/ SI/SK DE** NL BE/FR* GB/IE/PT/ ES/IT/GR/ LU/CH AT** CY/IS/MT HU PL Burner Orifice Pressure, mbar Capacity/ Model Diameter, mm Quantity Burner Orifice Part No. Gas Type Group Supply Pressure, mbar Natural Gas E 20 8.9 8.0 120 170 4.8 4.8 3 4 M411372 M411372 L.P. Gas B/P 30 No Governor 120 170 2.6 3.4 3 3 M411376 M400997 Natural Gas E 20 8.9 8.0 120 170 4.8 4.
Installation/Operation Supplement Exhaust Requirements Venting WARNING A drying tumbler produces combustible lint. To reduce the risk of fire, the tumbler must be exhausted to the outdoors. W057 To reduce the risk of fire and accumulation of combustible gases, DO NOT exhaust tumbler air into a window well, gas vent, chimney or enclosed, unventilated area such as an attic, ceiling, crawl space under a building, or concealed space of a building.
Installation/Operation Supplement Electrical Requirements WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. • Never start the tumbler with any guards/ panels removed.
Installation/Operation Supplement Steam Requirements Thermal Oil Prep Obtain specific steam service pipe sizes from the steam system supplier or a qualified steam fitter. It is the responsibility of the customer to install appropriate coil and heating system for thermal oil prep models. Alliance Laundry Systems, LLC. is not responsible for the performance or safety of the customer installed thermal oil system.
Installation/Operation Supplement 120 Pound Tumblers 2 1 11 12 3 6 4 13 10 5 9 8 7 6 TMB2014N TMB2014N NOTE: Refer to Table 3 for sizing of steam lines. Piping must also be sized accordingly for length of runs and number of elbows. 1 Supply 8 457 mm (18 in.) Drop 2 305 mm (12 in.
Installation/Operation Supplement 170 Pound Tumblers 1 SUPPLY 2 8 3 9 10 7 RETURN 6 2 5 4 3 TMB2024N TMB2024N NOTE: Refer to Table 4 for sizing of steam lines. Piping must also be sized accordingly for length of runs and number of elbows. 1 Risers 305 mm (12 in.) 6 457 mm (18 in.
Installation/Operation Supplement Operation WARNING To reduce the risk of fire: • DO NOT DRY articles containing foam rubber or similarly textured rubberlike materials. • DO NOT DRY plastics, anything containing wax or chemicals such as mops and cleaning cloths, or anything dry-cleaned at home with a dry-cleaning solvent. • DO NOT TUMBLE fiberglass curtains and draperies unless the label says it can be done. If they are dried, wipe out the cylinder with a damp cloth to remove particles of fiberglass.
Installation/Operation Supplement Control Instructions 4. Press the PUSH TO START button in, and hold it in for approximately three seconds. This starts the tumbler cycle. Manual Timer Control RT Control Suffix 1. Set the HEAT/DRYING timer for the number of minutes (from 0-60) desired. PUSH TO START TMB2146N 0 60 Figure 9 10 50 20 40 HEAT 30 TMB2142N Figure 6 2. Set the COOL DOWN/COOLING timer for the number of minutes (from 0-15) desired.
Installation/Operation Supplement Dual Digital Timer Control 4. Select reversing or nonreversing cylinder rotation settings, if applicable. RQ Control Suffix 1. Select HIGH, MED, LOW or NO HEAT by turning the temperature knob. TMB2145N Figure 13 TMB2147N 5. Press and release START button to start tumbler. Display will show minutes remaining before end of cycle. Figure 10 2. Set the HEAT TIME for the number of minutes (from 0-60) desired. TMB2150N Figure 14 TMB2148N Figure 11 3.
Installation/Operation Supplement Electronic OPL Control 2. Select REVERSING or NON-REVERSING cylinder rotation setting. H, L, P, S, U, X and Y Models with RM Control Suffix REVERSING 1. To use an Automatic Cycle, press an ON/ SELECT pad. Select HIGH, MEDIUM, MED LOW, LOW or NO HEAT for items that should not be dried with heat. A light to the left of the selected pad lights up. TMB1486N Figure 17 3. Press START pad to start tumbler.
Installation/Operation Supplement G and K Models with RM Control Suffix 3. Press START pad to start tumbler. 1. To use an Automatic Cycle, press a TEMPERATURE pad. Select HIGH, MED, LOW, DELICATE or NO HEAT for items that should not be dried with heat. A light to the left of the selected pad lights up. TMB2202N To use a Time Dry or Custom Cycle, refer to the Programming Manual. Figure 22 NOTE: All pads can be pressed in any sequence without damaging control or tumbler.
Installation/Operation Supplement Ignition Control Operation Diagnostic LED (DGN LED) / Error Codes The Diagnostic LED or DGN LED is located by the power connector on the ignition control. Refer to Figure 24. The Diagnostic LED will indicate the status of the ignition control. Refer to Table 5. LED Color Orange-Yellow Green Red Description Initialization Standby / Normal Operation Fault Indication Code Table 5 The Diagnostic LED will flash error codes one half second on and one half second off.
Installation/Operation Supplement Disposal of Unit This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Refer to Figure 25. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.