Electric and Gas Models Installation/Operation Clothes Dryer Original Instructions Keep These Instructions for Future Reference. CAUTION: Read the instructions before using the machine. (If this machine changes ownership, this manual must accompany machine.) DRY722C_SVG www.alliancelaundry.com Part No.
WARNING IMPORTANT: Purchaser must consult the local gas supplier for suggested instructions to be followed if the dryer user smells gas. The gas utility instructions plus the SAFETY and WARNING note directly above must be posted in a prominent location near the dryer for customer use. WARNING Risk of fire. Highly flammable material. WARNING W881 Read all instructions before using unit.
The following information applies to the state of Massachusetts, USA. • • • • This appliance can only be installed by a Massachusetts licensed plumber or gas fitter. This appliance must be installed with a 36 inch [910 mm] long flexible gas connector. A “T-Handle” type gas shut-off valve must be installed in the gas supply line to this appliance. This appliance must not be installed in a bedroom or bathroom. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 4 Part No.
Table of Contents ...............................................................................................................3 Safety Information..................................................................................7 Explanation of Safety Messages....................................................................... 7 Important Safety Instructions........................................................................... 7 Dimensions.........................................................
Start Dryer................................................................................................... 33 Indicator Lights............................................................................................ 34 Maintenance......................................................................................... 35 Lubrication...................................................................................................35 Care of Your Dryer..................................................
Safety Information Safety Information Explanation of Safety Messages • Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine. • DANGER • Indicates an imminently hazardous situation that, if not avoided, will cause severe personal injury or death.
Safety Information • • • • • • • • • • • • NOTE: The WARNING and IMPORTANT SAFETY INSTRUCTIONS appearing in this manual are not meant to cover all possible conditions and situations that may occur. Observe and be aware of other labels and precautions that are located on the machine. They are intended to provide instruction for safe use of the machine. Common sense, caution and care must be exercised when installing, maintaining, or operating the dryer.
Dimensions Dimensions Electric Dryers A K E B G F M H C D J I L DRY2672N_SVG A 23.5 in. [597 mm] B 8.375 in. [213 mm] C 28 in. [711 mm] D 0.4 in. [11 mm] E 8 in. [203 mm] F 46.62 in. [1184 mm] G *78.17 in. [1986 mm] H *4 in. [102 mm] I *4.5 in. [114 mm] J 26.875 in. [683 mm] K 15.4 in. [391 mm] L *15.44 in. [392 mm] M *39.13 in. [994 mm] NOTE: Exhaust openings are 4 inch [102 mm] metal ducting.
Dimensions Gas Dryers A L E B G M F P H N K C D I J O 1 DRY2673N_SVG 1. 3/8 in. N.P.T. Gas Connection A 23.5 in. [597 mm] B 8.375 in. [213 mm] C 28 in. [711 mm] D 0.4 in. [11 mm] E 8 in. [203 mm] F 46.62 in. [1184 mm] G *78.17 in. [1986 mm] H *4 in. [102 mm] I *4.5 in. [114 mm] J 26.875 in. [683 mm] K 2.3 in. [60 mm] L 15.4 in. [391 mm] M *44.87 in. [1140 mm] N *2.8 in. [70 mm] O *15.44 in. [392 mm] P *39.13 in.
Dimensions IMPORTANT: The dryer should have sufficient clearance around it for needed ventilation and for the ease of installation and servicing. For maximum drying performance, we recommend that more clearance be allowed around the dryer than the clearances that are listed throughout this manual. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 11 Part No.
Installation Installation Before You Start A Torx bit, part number 282P4, is available (as optional equipment at extra cost) for installing the Torx security screws. Supplies A Torx bit holder, part number 24161, is available (as optional equipment at extra cost) to be used with the Torx bit. For most installations, the basic supplies you will need are: 1 2 3 Position and Level the Dryer 4 1. Install the four rubber feet (in accessories bag). 2. Select a location with a solid floor.
Installation Front View A A DRY2667N_SVG Side View B D C E E 1 DRY2668N_SVG 1. Outer Wall of Enclosure Figure 3 Area Description Free Standing/Alcove Installation A Dryer sides 0 in. [0 mm] B Dryer top (rear 24 in. [610 mm]) 12 in. [305 mm] Table 1 continues... © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 13 Part No.
Installation Area Description Free Standing/Alcove Installation C* Dryer rear 4 in. [102 mm] D Dryer Top (front 4 in. [201 mm]) 0.5 in. [13 mm] E Exhaust duct clearance to combustible ma- 2 in. [51 mm] terial * Rear clearance is minimum. 6 inches [152 mm] is recommended when venting through rear of unit. Table 1 NOTE: For new installations, it is suggested to locate top of wall vent 42 inches (106.7 cm) above floor to make venting easier to connect.
Installation IMPORTANT: Installing in-line filters or lint collectors will cause increased static pressure. Failure to maintain the secondary lint system will decrease dryer efficiency and will void machine warranty. • • • • 1 2 DRY2540N_SVG 1. Correct 2. Incorrect Figure 4 • • • • • • • • • • • • • • • DO NOT use plastic, thin foil or type B ducting. Rigid metal duct is recommended. Locate dryer so exhaust duct is as short as possible.
Installation Weather Hood Type Number of 90° Elbows Recommended Use Only for Short Run Installations 1 1 D673I_SVG 1. 4 in. [102 mm] 1 D802I_SVG 1. 2.5 in. [64 mm] Maximum length of 4 in. [102 mm] diameter rigid metal duct. 0 65 feet [19.8 m] 55 feet [16.8 m] 1 55 feet [16.8 m] 47 feet [14.3 m] 2 47 feet [14.3 m] 41 feet [12.5 m] 3 36 feet [11.0 m] 30 feet [9.1 m] 4 28 feet [8.5 m] 22 feet [6.7 m] Table 2 NOTE: Deduct 6 feet [1.8 m] for each additional elbow.
Installation 1 2 4 3 DRY2674N_SVG 1. 2. 3. 4. 58786 Backdraft Damper (Available through your local authorized parts source) Clean Out Cover (Must be provided). Inspect monthly. Weather Hood or Sweep Elbow (No cap or screen) 24 in. [610 mm] Minimum Clearance to Roof/Ground Figure 5 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 17 Part No.
Installation Horizontal Exhaust Installation: Exhaust Air Flow Maximum Length of Duct 30 feet [9.1 m] 1 2 9 A B C D E F G H I J K 3 7 4 8 6 5 D686I_SVG 1. 2. 3. 4. 5. 6. 7. 8. 9. Where the exhaust duct pierces a combustible wall or ceiling, the opening must be sized per local codes. Wall 2 in. [50 mm] Minimum or Clearance per Local Codes No Screen or Cap 24 in.
Installation Vertical Exhaust Installation WARNING 3 4 To reduce the risk of gas leaks, fire or explosion: 2 • 1 • • 7 • 5 6 D753I_SVG Roof 24 in. [610 mm] Minimum Clearance to Roof/Ground No Screen or Cap Wall 2 in. [50 mm] Minimum Where the exhaust duct pierces a combustible wall or ceiling, an opening must be sized as shown or per local codes. 7. Connect to Dryer • 1. 2. 3. 4. 5. 6. • W315 1. Make certain your dryer is equipped for use with the type of gas in your laundry room.
Installation Natural Gas Altitude Adjustments Altitude 1 Orifice Size feet [m] inches [mm] # 5 Part Number 3,000 [915] 42 0.0935 [2.37] D503777 5,500 [1,680] 43 0.0890 [2.26] D503778 7,000 [2,135] 44 0.0860 [2.18] 58719 9,000 [2,745] 45 0.0820 [2.08] D503779 10,500 [3,200] 46 0.0810 [2.06] D503780 2 D233I_SVG 1. New Stainless Steel Flexible Connector – (Use design CSA certified connector) Use only if allowed by local codes 2. 1/8 in. NPT Pipe Plug 3.
Installation WARNING L.P. Altitude Adjustments Altitude Improper connection of the equipment earth/ground conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the dryer is properly connected to a protective earth/ground. Orifice Size feet [m] inches [mm] No. Part No. 3500 [1070] 54 0.0550 [1.40] D503785 7500 [2290] 55 0.0520 [1.32] 58755 11000 [3355] 56 0.0465 [1.
Installation Three-Wire Three-Wire Connection 1 2 1 2 3 8 3 4 7 4 D275I_SVG Four-Wire 5 2 6 3 1 D679I_SVG 1. 2. 3. 4. 5. 6. 7. 8. 4 D006I_SVG 1. 2. 3. 4. Typical Receptacle Power Cord Stain Relief Nut Strain Relief Figure 10 Figure 9 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Ground Wire Ground to Neutral Wire Neutral Terminal “L2” Terminal Center Wire (Neutral) Strain Relief (Not supplied with dryer) Ground Screw “L1” Terminal 22 Part No.
Installation NOTE: Dryer is shown with access cover removed for illustration purposes only. NEVER operate the dryer with access cover removed. Four-Wire Connection 1 Connecting Power Cord with Three-Wire Plug 4 3 2 5 1 6 7 8 9 1. 2. 3. 4. 5. 6. 7. 8. 9.
Installation 6 7 8 1 9 14 4 10 5 11 2 2 12 13 3 16 L1 L2 15 L1 L2 D816I_SVG 1. A typical 30-Amp Three-Wire Receptacle NEMA Type 10-30R 2. 120 ± 12 V.A.C. 3. 240 ± 12 V.A.C. 4. Intermediate Fuse Box (may be omitted if service entrance box is fused) 5. Wall Receptacle 6. Power Supply 7. 3-Wire Earth/Ground Neutral 120/240 Volt, 60 Hertz AC 1 Phase Service Entrance Switch Box (Refer to NOTE above) 8. 30 Ampere Fuses or Circuit Breaker 9. Neutral Wire 10.
Installation 3. Use a strain relief and insert end of power cord through power supply hole. 2 1 3 4 7 7 6 Figure 14 7 5 7 D696I_SVG 4. Use the three screws from the accessories bag to attach the power cord wires to the terminal block. Refer to Figure 15 . DRY2016N_SVG 3-Wire Connection 1. 2. 3. 4. 5. 6. 7. 1 2 Typical Four-Wire Receptacle Power Cord – Not Supplied with Dryer Strain Relief Nut Strain Relief 0 V.A.C. 240 ± 12 V.A.C. 120 ± 12 V.A.C. Figure 16 4 3 1.
Installation 4-Wire Connection 8 1 7 1 2 DRY2468N_SVG 1. Earth/Ground Screw 3 6 Figure 18 DRY2482N_SVG 1. 2. 3. 4. 5. 6. 7. 8. DRY2469N_SVG 1. Strain Relief Figure 19 5. Attach power cord earth/ground (green) wire to rear bulkhead using earth/ground screw removed in Step 3. 4 5 4. Use a strain relief and insert end of power cord through power supply hole. Neutral Terminal “L2” Terminal Black White Earth/Ground Red “L1” Terminal Earth/Ground to Neutral Wire Figure 20 6.
Installation The door on this dryer is completely reversible. To reverse door proceed as follows: 1. Remove four hinge attaching screws. D273P_SVG Figure 24 D675I_SVG 5. Remove door strike from door liner and reinstall on opposite side. Figure 21 2. Remove all nine screws. DRY1917N_SVG Figure 25 D272P_SVG 6. Insert liner under flange on bottom of door, then push top of door liner into place. Figure 22 3. Pull bottom of door liner out, then pull down, removing door liner from door panel.
Installation 8. Using screwdriver, remove two door plugs, and reinstall on opposite side of door opening. D317S_SVG Figure 28 9. Reinstall four hinge attaching screws, removed in Step 1. Figure 30 Plug In the Dryer D606I_SVG Figure 29 This appliance is to be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
Installation Gas Dryer Plug Cord Into Separately Fused 15 Amp Circuit Dryer requires 120 Volt, 60 Hertz electrical supply and comes equipped with a 3-prong earth/ground plug. Refer to serial plate for specific electrical requirements. NOTE: The wiring diagram is located behind the control panel, inside the control cabinet.
Installation 2. After the dryer has operated for three minutes, the exhaust air or exhaust pipe should be warm. WARNING This unit is equipped with a three-prong (earth/ ground) plug for your protection against shock hazard and should be plugged directly into a protective earth/ ground three-prong receptacle. Do not cut or remove the earth/ground prong from this plug. W823 WARNING Improper connection of the equipment earth/ground conductor can result in a risk of electric shock.
Installation Shut-off Valve Only Applicable on Certain Models 5 1 6 4 3 2 DRY2753N_SVG 1. 2. 3. 4. 5. 6. Air Shutter Lockscrew Air Shutter 1/8 in. [3.1 mm] Pipe Plug (For checking manifold pressure) Shut-off Valve Open Position Shut-off Valve Closed Position Shut-off Valve Handle Figure 33 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 31 Part No.
Operation Operation Operation Instructions WARNING To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS before operating this appliance. D717I_SVG Figure 35 W727 IMPORTANT: Remove all objects from pockets such as lighters and matches. This appliance shall not be used to dry off solvents or dry cleaning fluids. Close Loading Door 1. Close loading door. 2. Dryer will not operate with the door open.
Operation HIGH TEMP LOW TEMP MED TEMP DELICATES NO HEAT START DRY2534N_SVG Figure 38 Insert Coins or Card DRY2633N_SVG To Insert Coins 1. Insert coin(s) in coin slot. 2. Check pricing as seen on digital display. Figure 40 Start Dryer 1. To start dryer, push START pad. 2. To stop dryer at any time, open the door. 3. To restart the dryer, close door and push START pad. Cycle is completed when time remaining reaches 00 minutes.
Operation WARNING To prevent the risk of fire, never stop a dryer before the end of the drying cycle unless all items are quickly removed and spread out so that the heat is dissipated. W756 NOTE: This machine includes an extended tumble feature. Starting 20 minutes after a cycle ends, the cylinder will tumble for two minutes every hour without heat, up to 18 hours or until door is opened.
Maintenance Maintenance Lubrication WARNING All moving parts are sealed in a permanent supply of lubricant or are equipped with oilless bearings. Additional lubrication will not be necessary. Any disassembly requiring the use of tools must be performed by a suitably qualified service person. Care of Your Dryer W299 WARNING To reduce the risk of an electric shock, serious injury or death, disconnect the electrical service to the dryer before cleaning the interior.
Maintenance Motor Overload Protector The dryer’s motor overload protector stops the motor automatically in the event of an overload. After cooling, the overload protector will reset itself. Dryer can be restarted by pressing the START pad. If overload protector cycles again, remove the dryer from use and call the service person to correct the problem. For Energy Conservation • • • • • • • • • • Make sure the lint filter is always clean. Do not overload dryer. Do not overdry clothes.
Troubleshooting Troubleshooting Try these troubleshooting tips before making a service call. They may save you time and money. Dryer Symptom Dryer won’t start Possible Cause/Solution • • • • • • • Dryer won’t heat • • • • • • Dryer doesn’t dry clothes satisfactorily • • • • • Dryer is noisy • • • Insert coin(s) or card, if required. For dryers equipped with a power cord, make sure the power cord is plugged all the way into the electrical outlet. Make sure loading door is closed. Press START pad.
Troubleshooting Dryer Symptom Possible Cause/Solution Clothes are too wrinkled • • Check heat setting. Overdrying can cause wrinkling. Check load size. Large loads may not tumble properly and may cause wrinkling. Clothes have odor • Check room for odors before drying clothes. Any odor (fried foods, paint, varnish, cleaners, burning wood, etc.) will transfer to clothing as the dryer draws air from the room. Ventilate room before drying clothes.
Contact Information Contact Information If service is required, contact the nearest Factory Authorized Service Center. Model Number If you are unable to locate an authorized service center or are unsatisfied with the service performed on your unit, contact: Alliance Laundry Systems Shepard Street P.O. Box 990 Ripon, WI 54971-0990 U.S.A. www.alliancelaundry.com Phone: +1 (920) 748-3121 Serial Number Please include a copy of your bill of sale and any service receipts you have.
Installer Checklist Installer Checklist Fast Track for Installing the Dryer 1 Position and Level the Dryer. 6 CHECK Wipe Out Inside of Dryer. CHECK DRY2634N_SVG 2 Connect Dryer Exhaust System. 7 CHECK Plug In the Dryer. Electric CHECK DRY2540N_SVG1 D275I_SVG1 Gas TLW2289N_SVG 3 GAS ONLY • • 8 Recheck Steps. Connect Gas Supply Pipe. Check for Gas Leaks. D233I_SVG1 CHECK 4 CHECK ELECTRIC ONLY • 9 Connect Electrical Cord.