Installation Instructions for Dryers Original Instructions Keep These Instructions for Future Reference. CAUTION: Read the instructions before using the machine. (If this machine changes ownership, this manual must accompany machine.) www.alliancelaundry.com Part No.
WARNING IMPORTANT: Purchaser must consult the local gas supplier for suggested instructions to be followed if the dryer user smells gas. The gas utility instructions plus the SAFETY and WARNING note directly above must be posted in a prominent location near the dryer for customer use. WARNING Risk of fire. Highly flammable material. WARNING W881 Read all instructions before using unit.
The following information applies to the state of Massachusetts, USA. • • • • This appliance can only be installed by a Massachusetts licensed plumber or gas fitter. This appliance must be installed with a 36 inch [910 mm] long flexible gas connector. A “T-Handle” type gas shut-off valve must be installed in the gas supply line to this appliance. This appliance must not be installed in a bedroom or bathroom. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 4 Part No.
Table of Contents Dimensions............................................................................................. 6 Installation............................................................................................. 8 Before You Start............................................................................................. 8 Supplies..................................................................................................... 8 Order of Installation Steps.............................
Dimensions Dimensions Electric Models A B G I K J C E H D F A * 40.42 in. [1027 mm] B * 39.61 in. [1006 mm] C * 15.44 in. [392 mm] D * 4 in. [102 mm] E 15.4 in. [391 mm] F 26.875 in. [683 mm] G * 4.5 in. [114 mm] H 0.4 in. [10 mm] I 8 in. [203 mm] J 28 in. [711 mm] K 23.5 in. [597 mm] NOTE: Exhaust openings are 4 inch [102 mm] metal ducting. DRY2638N_SVG * With leveling legs turned into base.
Dimensions A *40.42 in. [1027 mm] B *39.61 in. [1006 mm] C *15.44 in. [392 mm] D *2.8 in. [70 mm] E 2.3 in. [60 mm] F 15.4 in. [391 mm] G 26.875 in. [683 mm] H 4 in. [102 mm] I *4.5 in. [114 mm] J 0.4 in. [10 mm] K 8 in. [203 mm] L 28 in. [711 mm] M 23.5 in. [597 mm] NOTE: Exhaust openings are 4 inch [102 mm] metal ducting. * With leveling legs turned into base. NOTE: Gas models cannot be vented out left side of cabinet because of burner housing.
Installation Installation Before You Start 4. For electric models only, connect the electrical cord. 5. Reverse the door, if desired. 6. Wipe out the inside of the dryer. 7. Plug in the dryer. 8. Recheck steps. 9. Start and run the dryer in a heat setting to verify dryer is heating. Supplies For most installations, the basic supplies you will need are: 1 2 3 4 Position and Level the Dryer 1. Install dryer before washer. This allows room for attaching exhaust duct. 2.
Installation Front View (Without Closet Door) B A A DRY2640N_SVG Side View (Closet Door) 1 E D A H 3 C DRY2641N_SVG Front View (Closet Door) F 2 (G) F DRY2637N_SVG 1. Closet Door 2. Centered Air Openings (G) (2 Openings minimum) 3. Outer Wall of Enclosure Figure 3 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 9 Part No.
Installation Area Free Standing/Alcove Installation Description Closet Installation A* Dryer sides and rear clearance 0 in. [0 mm] 0 in. [0 mm] B Dryer top clearance 12 in. [305 mm] 12 in. [305 mm] C Dryer front clearance Not Applicable 2 in. [51 mm] D Exhaust duct clearance to com- 2 in. [51 mm] bustible material 2 in. [51 mm] E Weather hood to ground clearance 12 in. [305 mm] 12 in. [305 mm] F Distance from floor or ceiling to air opening edge Not Applicable 3 in.
Installation • WARNING To reduce the risk of fire, DO NOT use plastic or thin foil ducting to exhaust the dryer. • • W354 • WARNING To reduce the risk of fire, the exhaust duct and weather hood MUST be fabricated of a material that will not support combustion. Rigid or flexible metal pipe is recommended for a clothes dryer. W048 • • • • • • WARNING To reduce the risk of fire due to increased static pressure, we do not recommend installation of inline secondary lint filters or lint collectors.
Installation Exhausting the dryer through sides or bottom can be accomplished by installing a Directional Exhaust Kit, 528P3, available as optional equipment at extra cost. To prevent backdraft when dryer is not in operation, outer end of exhaust pipe must have a weather hood with hinged dampers (obtain locally). Exhaust System NOTE: Weather hood should be installed at least 12 inches [305 mm] above the ground. Larger clearances may be necessary for installations where heavy snowfall can occur.
Installation WARNING Natural Gas Altitude Adjustments Altitude Orifice Size To reduce the risk of gas leaks, fire or explosion: • • • • • • The dryer must be connected to the type of gas as shown on nameplate located in the door recess. Use a new flexible stainless steel connector. Use pipe joint compound insoluble in L.P. (Liquefied Petroleum) Gas, or Teflon tape, on all pipe threads. Purge air and sediment from gas supply line before connecting it to the dryer.
Installation L.P. Altitude Adjustments 1 Altitude 5 feet [m] Orifice Size No. inches [mm] Part No. 2 3 4 3000 [915] 55 0.0520 [1.32] 58755 8000 [2440] 56 0.0465 [1.18] D503786 Table 4 Electric Dryer Only - Connect Electrical Plug D233I_SVG 1. New Stainless Steel Flexible Connector – (Use design CSA certified connector) Use only if allowed by local codes 2. 1/8 in. NPT Pipe Plug 3. Equipment Shut-Off Valve 4. Black Iron Pipe: Shorter than 20 ft. [6.1 m] – Use 3/8 in. [9.5 mm] pipe.
Installation WARNING Wire Length Improper connection of the equipment earth/ground conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the dryer is properly connected to a protective earth/ground. W886 Do not modify the plug provided with the cord-kit - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
Installation 6 7 8 1 9 14 4 10 5 11 2 2 12 13 3 16 L1 L2 15 L1 L2 D816I_SVG 1. A typical 30-Amp Three-Wire Receptacle NEMA Type 10-30R 2. 120 ± 12 V.A.C. 3. 240 ± 12 V.A.C. 4. Intermediate Fuse Box (may be omitted if service entrance box is fused) 5. Wall Receptacle 6. Power Supply 7. 3-Wire Earth/Ground Neutral 120/240 Volt, 60 Hertz AC 1 Phase Service Entrance Switch Box (Refer to NOTE above) 8. 30 Ampere Fuses or Circuit Breaker 9. Neutral Wire 10.
Installation 3. Use a strain relief and insert end of power cord through power supply hole. 2 1 3 4 7 7 6 Figure 8 7 5 7 D696I_SVG 4. Use the three screws from the accessories bag to attach the power cord wires to the terminal block. Refer to Figure 9 . DRY2016N_SVG 3-Wire Connection 1. 2. 3. 4. 5. 6. 7. 1 2 Typical Four-Wire Receptacle Power Cord – Not Supplied with Dryer Strain Relief Nut Strain Relief 0 V.A.C. 240 ± 12 V.A.C. 120 ± 12 V.A.C. Figure 10 4 3 1. Disconnect power to dryer.
Installation 4-Wire Connection 8 1 7 1 2 DRY2468N_SVG 1. Earth/Ground Screw 3 6 Figure 12 DRY2482N_SVG 1. 2. 3. 4. 5. 6. 7. 8. DRY2469N_SVG 1. Strain Relief Figure 13 5. Attach power cord earth/ground (green) wire to rear bulkhead using earth/ground screw removed in Step 3. 4 5 4. Use a strain relief and insert end of power cord through power supply hole. Neutral Terminal “L2” Terminal Black White Earth/Ground Red “L1” Terminal Earth/Ground to Neutral Wire Figure 14 6.
Installation The door on this dryer is completely reversible. To reverse door proceed as follows: 1. Remove four hinge attaching screws. D273P_SVG Figure 18 DRY2052N_SVG 5. Remove door strike from door liner and reinstall on opposite side. Figure 15 2. Remove all nine screws. DRY1917N_SVG Figure 19 D272P_SVG 6. Insert liner under flange on bottom of door, then push top of door liner into place. Figure 16 3. Pull bottom of door liner out, then pull down, removing door liner from door panel.
Installation 8. Using screwdriver, remove two door plugs, and reinstall on opposite side of door opening. Electric Dryer Connect the dryer to an electrical power source. Refer to Connect Electrical Plug section for information on connecting power cord. Connect to 30 Amp Circuit DRY2503N_SVG D275I_SVG2 Figure 22 9. Reinstall four hinge attaching screws, removed in Step 1. Figure 25 Gas Dryer Dryer requires 120 Volt, 60 Hertz electrical supply and comes equipped with a 3-prong earth/ground plug.
Installation Plug Cord Into Separately Fused 15 Amp Circuit 2 WARNING This unit is equipped with a three-prong (earth/ ground) plug for your protection against shock hazard and should be plugged directly into a protective earth/ ground three-prong receptacle. Do not cut or remove the earth/ground prong from this plug. 3 1 8 6 W823 WARNING 7 4 Improper connection of the equipment earth/ground conductor can result in a risk of electric shock.
Installation 2. Close the loading door and start the dryer in a heat setting (refer to the operation instructions). The dryer will start, the igniter will glow red and the main burner will ignite. IMPORTANT: If all air is not purged out of gas line, gas igniter may go off before gas is ignited. If this happens, after approximately two minutes igniter will again attempt gas ignition. IMPORTANT: If igniter does not light, make sure gas is turned on. 3.
Installer Checklist Installer Checklist Fast Track for Installing the Dryer 1 Position and Level the Dryer. 5 CHECK Reverse Door, if Desired. CHECK DRY2634N_SVG DRY2052N_SVG1 2 Connect Dryer Exhaust System. 6 CHECK Wipe Out Inside of Dryer. CHECK DRY2501N_SVG1 3 GAS ONLY • Connect Gas Supply Pipe. • Check for Gas Leaks. DRY2504N_SVG1 7 CHECK Plug In the Dryer. Electric CHECK D275I_SVG1 Gas D233I_SVG1 D254I_SVG 4 ELECTRIC ONLY 8 Recheck Steps. Connect Electrical Cord.