User’s Manual Pub. 0300247-01 Rev.
ii MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) Important Notes 1. Please read all the information in this owner’s guide before installing the product. 2. The information in this owner's guide applies to hardware Series A and firmware version 1.00 or later. 3. This guide assumes that the reader has a full working knowledge of the relevant processor. Notice The products and services described in this owner's guide are useful in a wide variety of applications.
iii Table of Contents IMPORTANT NOTES............................................................................................................................................ II NOTICE .............................................................................................................................................................. II LIMITED WARRANTY ..........................................................................................................................................
iv MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) PREFACE Read this preface to familiarize yourself with the rest of the manual.
v Conventions Used in This Manual The following conventions are used throughout this manual: Bulleted lists (like this one) provide information not procedural steps. Numbered lists provide sequential steps or hierarchical information. Italic type is used for emphasis Bold type identifies headings and sub-headings ! Attention Are used to identify critical information to the reader User’s Manual Pub. 0300247-01 Rev.
vi MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) User’s Manual Pub. 0300247-01 Rev.
Chapter 1 Module Overview The 1762sc-IF4OF4 Combo module contains 4 analog output channels and 4 analog input channels. The 4 analog output channels (Ch 0 through 3) can be configured for either voltage or current. The first two input channels (Ch 4 & 5) can be configured for current only. The second pair of input channels (Ch 6 & 7) can be configured for current, voltage or thermocouple.
1-2 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) Section 1.3 Input Types and Ranges The table below lists the input types and their associated ranges. Table 1-2 (Input Types) Input Type Range E Type Thermocouple -200 to 1000 ˚C (-328 to 1832 ˚F) J Type Thermocouple -180 to 1200 ˚C (-292 to 2192 ˚F) K Type Thermocouple -200 to 1370 ˚C (-328 to 2498 ˚F) T Type Thermocouple -190 to 400 ˚C (-310 to 752 ˚F) 0 to 5V (0 to 5.5V) 1 to 5V (0 to 5.
Chapter 1: Module Overview 1-3 Section 1.5 Filter Frequencies For input channels, the module uses a digital filter that provides high frequency noise rejection for each input signal. The filter for each channel is programmable allowing you to select from four different filter frequencies: 4 Hz 17 Hz 62 Hz 470 Hz Section 1.6 Hardware Features Channels are wired as differential inputs or single ended outputs.
1-4 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) 6 Flat ribbon cable with bus connector (female) 7 Terminal block 8 DIN rail latch 9 Pull loop 1.6.1 LED Indicator The 1762 combo module uses a single green LED to show operational status of the module.
Chapter 1: Module Overview 1-5 continuously samples the CJC sensor and compensates for temperature changes at the terminal block cold junction, between the thermocouple wire and the terminal connector. Output Channels The module’s output channel uses a digital-to-analog (D/A) converter to read the digital output data from the controller and convert it to an analog output signal. See the block diagram below. ASIC User’s Manual Pub. 0300247-01 Rev.
1-6 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) User’s Manual Pub. 0300247-01 Rev.
Chapter 2 Installation and Wiring This chapter will cover: Compliance to European union directives Power requirements General considerations Mounting Field wiring connections Module Indicators Section 2.1 Compliance to European Union Directives This product is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following directives. 2.1.
2-2 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) 5 VDC 24 VDC 30 mA 3.0W Max (125mA max at 24V) Use the table below to determine the maximum number of IF4OF4 modules that can be installed in a MicroLogix system. Table 2-1 Controller ML1100 ML1200 (24pt.) ML1200 (40pt.) ML1400 (All) Max 5V Bus Current 800 400 600 1500 Max 24V Bus Current 700 350 500 1500 Max # of IF4OF4 Modules 4 3 3 7 Section 2.
Chapter 2: Installation and Wiring ! Attention 2-3 EXPLOSION HAZARD Substitution of components may impair suitability for Class I, Division 2. Do not replace components or disconnect equipment unless power has been switched off or the area is known to be nonhazardous. Do not connect or disconnect components unless power has been switched off or the area is known to be non-hazardous. This product must be installed in an enclosure. All wiring must comply with N.E.C. article 501-4(b). 2.3.
2-4 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) Section 2.4 Mounting ! Attention Do not remove protective debris strip until after the module and all other equipment near the module is mounted and wiring is complete. Once wiring is complete and the module is free of debris, carefully remove protective debris strip. Failure to remove strip before operating can cause overheating. 2.4.1 Minimum Spacing Maintain spacing from enclosure walls, wireways, adjacent equipment, etc. Allow 50.
Chapter 2: Installation and Wiring 2-5 Figure 2-2 Note: For environments with extreme vibration and shock concerns, use the panel mounting method described below, instead of DIN rail mounting. 2.4.3 Panel Mounting Use the dimensional template shown below to mount the module. The preferred mounting method is to use two M4 or #8 Pan Head screws per module. M3.5 or #6 Pan Head screws may also be used, but a washer may be needed to ensure a good ground contact. Mounting screws are required on every module.
2-6 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) Figure 2-4 Note: Use the pull loop on the connector to disconnect modules. Do not pull on the ribbon cable. EXPLOSION HAZARD In Class I, Division 2 applications, the bus connector must be fully seated and the bus connector cover must be snapped in Attention place. In Class I, Division 2 applications, all modules must be mounted in direct contact with each other as shown on page 24.
Chapter 2: Installation and Wiring 2-7 wires specified by the thermocouple manufacturer. Using the incorrect type of thermocouple extension wire or not following the correct polarity will cause invalid readings. The module does not provide loop power for analog inputs. Use a power supply that matches the input transmitter specifications. Outputs Load resistance for a voltage output channel must be equal to or greater than 1K Ω.
2-8 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) To limit the pickup of electrical noise, keep thermocouple and millivolt signal wires as far as possible from power and load lines. If noise persists for a device, try grounding the opposite end of the cable shield or ground both ends of the shield. 2.6.1 Wiring Diagram Refer to the following wiring diagrams for field wiring connections. Figure 2-5 (Wiring Diagram) Voltage/TC Input Path 2.6.
Chapter 2: Installation and Wiring ! Attention 2-9 Be careful when stripping wires. Wire fragments that fall into a module could cause damage when power is applied. Once wiring is complete, ensure the module is free of all metal fragments. When wiring the terminal block, keep the finger-safe cover in place. 1) Refer to section 2.6.1for proper field wiring connections. 2) Route the wire under the terminal pressure plate. You can use the stripped end of the wire or a spade lug.
2-10 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) Blink Code Description Blinks rapid green The module is not in run mode Solid Green Startup has completed, all internal tests have passed and the module has received a valid configuration from the PLC Off Hardware error User’s Manual Pub. 0300247-01 Rev.
Chapter 3 Configuring the 1762sc-IF4OF4 Using RSLogix 500 This chapter covers the following subjects: Things you should know Module memory map Add module to Logix 500 Module configuration Reading input data Module update time Section 3.1 Things You Should Know This chapter describes how to configure the IF4OF4 module for the MicroLogix 1100, 1200 and 1400 system using RSLogix 500 programming software. Section 3.
3-2 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) Section 3.3 Add Module to Logix 500 The following procedure describes how to add the IF4OF4 module to the RSLogix 500 programming software. 1.) Create a new RSLogix 500 project and select either a Micro 1100, 1200, or 1400 processor. 2.) Double-click “I/O Configuration” from the project tree. 3.) Select the first empty slot and then double-click the “Other—Requires I/O Card Type ID” option, from the I/O configuration screen. 4.
Chapter 3: Configuring the 1762sc-IF4OF4 for RSLogix 500 3-3 5.) Repeat steps 1 through 4 for additional modules. Section 3.4 Module Configuration The IF4OF4 is configured using the output data table within RSLogix 500. 3.4.1 Output Data File (Configuration Data) The output data file is used to configure the advanced settings of the module including input type, output type, data format, filter settings, etc. Use the addressing scheme below to locate the 8 output words needed to configure the module.
3-4 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) Register Function Output File (Used for Module Configuration) High byte: Channel 1 Configuration Register (Output) 1 O:e.5 Low byte: Channel 2 Configuration Register (Output) 1 High byte: Channel 3 Configuration Register (Output) 1 O:e.6 Low byte: Channel 4 Configuration Register (Input) 2 High byte: Channel 5 Configuration Register (Input) 2 O:e.
Chapter 3: Configuring the 1762sc-IF4OF4 for RSLogix 500 Output Range 0 to 5V 0 to 10V 1 to 5V Output Value Condition Raw/Prop -10.00 V dc -11.00 V dc 5.50 V dc 5.00 V dc 0.00 V dc 0.00 V dc 11.00 V dc 10.00 V dc 0.00 V dc 0.00 V dc 5.50 V dc 5.00 V dc 1.00 V dc 0.
3-6 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) 3.4.4 Input Channel Configuration (Channels 6 and 7) Channels 6 and 7 can be configured for current or voltage, including thermocouple inputs. The following table describes the configuration options for channels 6 and 7.
Chapter 3: Configuring the 1762sc-IF4OF4 for RSLogix 500 Input Range E Thermocouple T Thermocouple 0..5V 1..5V +/-10V 0..10V 4..20mA 0..20mA CJC Input Value 1000.00 deg C 1000.00 deg C -200.00 deg C -200.00 deg C 400.00 deg C 400.00 deg C -190.00 deg C -190.00 deg C 5.50 V dc 5.00 V dc 0.00 V dc 0.00 V dc 5.50 V dc 5.00 V dc 1.00 V dc 0.00 V dc 11.00 V dc 10.00 V dc -10.00 V dc -11.00 V dc 11.00 V dc 10.00 V dc 0.00 V dc 0.00 V dc 20.40 mA 20.00 mA 4.00 mA 3.92 mA 20.40 mA 20.00 mA 0.00 mA 0.
3-8 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) Section 3.5 Read Input Data The input data file contains module status information and analog input data for each of the four input channels. Analog input data is read for each channel, converted to a scaled digital value, and stored in the input file. Use the addressing scheme below to locate the 8 input words used for channels 0 through 7, respectively. (1) I/O located on the controller (embedded I/O) is slot 0.
Chapter 3: Configuring the 1762sc-IF4OF4 for RSLogix 500 3-9 output voltage or current (depending on the output type) down to the “Low Limit” value. O = Over range flag bits: Applies to all input/output types. Inputs: When set to 1 indicates input signal is above the “High Range” value. Module will continue to convert analog data to the maximum “High Limit” value. Bit is automatically reset (0) by the module when the over range condition clears.
3-10 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) User’s Manual Pub. 0300247-01 Rev.
Appendix A Module Specifications General Specifications Specification Value Dimensions 90 mm (height) x 87 mm (depth) x 40 mm (width) height including mounting tabs is 110 mm 3.54 in. (height) x 3.43 in. (depth) x 1.58 in. (width) height including mounting tabs is 4.33 in. Approximate Shipping Weight (with carton) 281g (0.619 lbs.
A-2 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) Specification Value Hazardous Environment Class Class I, Division 2, Hazardous Location, Groups A, B, C, D (ISA 12.12.01, C-UL under CSA C22.2 No.
Appendix A: Specifications Specification Calibrated Accuracy Thermocouple Inputs Value Linearization per ITS-90 System accuracy at 25°C (4 and 17 Hz filters): Type J (-180°C to 1200°C): ±1.0 degrees C maximum Type K (-200°C to 1370°C): ±2.0 degrees C maximum Type E (-200°C to 1000°C): ±1.0 degrees C maximum Type T (-190°C to 400°C): ±2.0 degrees C maximum System accuracy at -20-60 C (4 and 17 Hz filters): Type J (-180°C to 1200°C): ±5.0 degrees C maximum Type K (-200°C to 1370°C): ±6.
A-4 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) Specification Value Current Inputs System accuracy at 25° C (4 and 17 Hz filters): ± 20 uA maximum for 0-20 mA inputs ± 20 uA maximum for 4-20 mA inputs System accuracy at -20-60°C (4 and 17 Hz filters): ± 50 uA maximum for 0-20 mA inputs ± 50 uA maximum for 4-20 mA inputs Input Repeatability Input Repeatability (at 25C) 4Hz Filter 17Hz Filter Thermocouples Type J Type K Type T Type E Voltage Inputs Current Inputs ± 0.3 °C ± 0.4 °C ± 0.
Appendix A: Specifications Specification Description Maximum Output Inductive and 0.1mH Capacitive Load 1µF Output Settling Time <1ms to 63% of full scale Output Channel glitch) Current mode = < ± 1V for 20ms at maximum load Voltage mode = < ± 0.4V for 20ms and < ±- 1V for 1.5ms with 1k ohm load ±24V @25dec C for 1 minute on any channel, with any range and value Output Protection Output Short Circuit Protection User’s Manual Pub. 0300247-01 Rev. C Yes, continuous.
A-6 MicroLogix™ 1200 Analog Combo Module (4Ch IN / 4Ch Out) User’s Manual Pub. 0300247-01 Rev.
Index Input Type ∙ 1‐1 A L Addressing ∙ 3‐3, 3‐8 LED ∙ 1‐4, 2‐9 Low Voltage Directive ∙ 2‐1 B block diagram ∙ 1‐5 C Configuration ∙ 3‐3 D M Memory Map ∙ 3‐1 Module Update Time ∙ 3‐9 Mounting DIN ∙ 2‐4 Panel ∙ 2‐5 N Data Format ∙ 1‐2 Door Label ∙ 2‐9 Noise ∙ 2‐3, 2‐7 E O EMC Directive ∙ 2‐1 Output Type ∙ 1‐1 F P Filter Frequencies ∙ 1‐3 Power Requirements ∙ 2‐1 power‐up ∙ 1‐4 G Grounding ∙ 2‐7 H S Slot number ∙ 3‐3 Slot Number ∙ 3‐8 Spacing Minimum ∙ 2‐4 Hazardous Location ∙ 2‐2 W I In
User’s Manual Pub. 0300247-01 Rev.
Getting Technical Assistance Note that your module contains electronic components which are susceptible to damage from electrostatic discharge (ESD). An electrostatic charge can accumulate on the surface of ordinary plastic wrapping or cushioning material. In the unlikely event that the module should need to be returned to Spectrum Controls, please ensure that the unit is enclosed in approved ESD packaging (such as static-shielding / metalized bag or black conductive container).
©2009, Spectrum Controls, Inc. All rights reserved. Specifications subject to change without notice. The Encompass logo and ControlLogix are trademarks of Rockwell Automation. Corporate Headquarters Spectrum Controls Inc. P.O. Box 6489 Bellevue, WA 98006 USA Fax: 425-641-9473 Tel: 425-746-9481 Web Site: www.spectrumcontrols.com E-mail: spectrum@spectrumcontrols.com User’s Manual Pub. 0300247-01 Rev.