Instruction Manual

Appendix A: Module Specifications 83
The following table provides the maximum error for each RTD and
resistance type when the 10 Hz, 50 Hz, and 60 Hz filters are used and the
module is operating at 0°C to 60°C and was at that temperature. Errors
due to lead wire resistance mismatches are not included.
Input Max. Error
Type 0°C to 60°C
100 Pt 385 ±3.3°C
200 Pt 385 ±2.8°C
500 Pt 385 ±3.0°C
1000 Pt 385 ±2.9°C
100 Pt 3916 ±2.7°C
200 Pt 3916 ±2.4°C
500 Pt 3916 ±2.3°C
1000 Pt 3916 ±2.2°C
10 Cu 426 ±4.5°C
120 Ni 618 ±0.8°C
120 Ni 672 ±0.8°C
3000 Resistance ±7.0
The diagrams that follow provide data from a sample module for a given
RTD type over a range of inputs, over temperature.
100
Pt 385 RTD, Example Deviations
-1.4
-1.3
-1.2
-1.1
-1
-0.9
-0.8
-0.7
-0.6
-0.5
-0.4
-0.3
-0.2
-0.1
0
0.1
-200 -100 0 100 200 300 400 500 600 700 800 900
Degrees C RTD Input
Degrees C Deviation
Ch 7 Delta, 25C
Ch 7 Delta, 0C
Ch 7 Delta, 60C