50 KHz Counter / Flowmeter Module
Input Registers - Channel
Data
The channel data consists of 4 words, the lower counter data value, the
rate data high value, the rate data low value and the channel status data.
Table A.1 - Data Word Addresses
CTR8 CTR4 Scale/Limit Value
I:e.0 to I:e.3 I:e.0 to I:e.3 0 Channel LSW, Rate Data High, Rate Data Low, Status Reg
I:e.4 to I:e.7 I:e.4 to I:e.7 1 Channel LSW, Rate Data High, Rate Data Low, Status Reg
I:e.8 to I:e.11 I:e.8 to I:e.11 2 Channel LSW, Rate Data High, Rate Data Low, Status Reg
I:e.12 to I:e.15 I:e.12 to I:e.15 3 Channel LSW, Rate Data High, Rate Data Low, Status Reg
I:e.16 to I:e.19 (n/a) 4 Channel LSW, Rate Data High, Rate Data Low, Status Reg
I:e.20 to I:e.23 (n/a) 5 Channel LSW, Rate Data High, Rate Data Low, Status Reg
I:e.24 to I:e.27 (n/a) 6 Channel LSW, Rate Data High, Rate Data Low, Status Reg
I:e.28 to I:e.31 (n/a) 7 Channel LSW, Rate Data High, Rate Data Low, Status Reg
Figure A.2 - Data Words
89
I
:e.w
I
:e.x
I
:e.y
I
:e.z
Rate Output Low
Counter LSW
Rate Output High
Status Output
Data Words for Floating Point Rate Mode