Instruction Manual

TM 799200 Rev (C), January 2014
Environmental Specifications 27
4.4.3 Humidity
Designed to meet MIL-STD-810C, method 507.1, procedure IV relative
humidity of up to 95% for the operational temperature range.
4.4.4 Salt and Fog
Designed to meet MIL-STD-810C, method 509.1 procedure I. Exposure to a
5% salt solution for 48 hours.
4.4.5 Water and Dust
IP67 per EN60529
IP66 per EN60529
Dust:
Totally protected against dust
Liquids:
Protected against immersion between 15
cm and 1m in depth. Protected against
all water jets from all directions.
4.4.6 Shock and Vibration
Vibration:
Designed to meet MIL-STD-810C,
method 514.2, procedure VIII.
Mechanical Shock:
Designed to meet MIL-STD-810C,
method 516.1, procedure I.
4.4.7 Electromagnetic Compatibility (EMC):
This product is in conformance with EMC directive 89/336/EC.
Radiated Emission:
EN61000-6-3
Conducted Emission:
EN61000-6-3
Radiated Immunity:
EN61000-4-3
Conducted Immunity:
EN61000-4-6
ESD:
EN61000-4-2
Burst:
EN61000-4-4
Surge:
EN61000-4-5