Product Manual

27
16 TECHNICAL DATA
16.1 UL633N
Leveling accuracy
1,3
: ±0.5mm/10m,1/16“@100ft,10arcseconds
Gradeaccuracy
1,3
: ±1.0mm/10m,1/8“@100ft,20arcseconds
Gradetemperaturedriftsensitivity: ±0,3mm/10m/1°C;1/16”@310ft.@1°F
Rotation: 0-750rpm
Scanmode: 5presetsizes+variableadjustment
Operational area
1,2
: appr.400m(1300feet)radiuswithdetector
Lasertype: 650nm
Laserclass: Class3
Self-levelingrange: appr.±14°
Graderange(Y;X): ±25%bothaxes(notsimultaneously)
Graderange(Z): ±25%
Levelingindicators: LCDindicationsandLEDashes
Radiorange(HL760)
1,2,4
: upto150m(490ft)
Powersource: 4x1,5VDalkalinebatteriesorNiMHbatterypack
Batterylife
1
: 35hoursNiMH;40hoursalkaline
Operatingtemp.: -20°Cto50°C(-4°Fto122°F)
Storagetemp.: -20°Cto70°C(-4°Fto158°F)
Tripodattachments: 5/8x11horizontallyandvertically
DustandWaterproof: IP67
Weight: 3.1kg(6.8lbs)
Lowvoltageindication: LCDbatteryindicator
Lowvoltagedisconnection: unitshutsoff
16.2 Remote Control RC603N
RadioOperatingrange
1,2,4
: upto150m(490ft)
IROperatingrange
1
: upto80m(260ft)
Powersource: 2x1.5VAAalkalinebatteries
Batterylife
1
: 130hours
DustandWaterproof: IP66
Weight: 0.26kg(0.4lbs)
16.3 Spot Finder SF601
Operating range
1,2,4
: upto80m(260ft)
Powersource: 4x1.5VAAalkalinebatteries
Batterylife
1
: 30hours
DustandWaterproof: IP67
Weight: 0.43kg(0.4lbs)
1) at 21°Celsius
2) under optimal atmospheric circumstances
3) along the axis
4) Heigt of instruments 1m (e.g. with tripod)
17 DECLARATION OF CONFORMITY
We
Trimble Kaiserslautern GmbH
Declareunderoursoleresponsibilitythattheproducts
UL633N and RC603N
Towhichthisdeclarationrelatesisinconformitywiththefollowingstandards:
EN 50371:2002, EN 60825-1:2014, ETSI EN 300328 V1.7.1:2006, ETSI EN 301489-1 V1.9.2:2011,
ETSI EN 301489-3 V1.4.1:2002
following the provisions of directive R&TTE 1999/5/EC.
The managing director