User Manual User guide

User’s Manual – GPS Mode
312
The base reference position is received over the radio link,
and Survey Pro finds your original base point. Tap Next> and
Set to complete GPS Setup.
The Data Collection screen opens and you are ready to collect
data
4. Check point
Tap Control, and select point 1 to occupy as a Check. The
results should be near perfect.
5. Data Collection
Occupy b1,b2,b4,bChap,bMane as data collection points.
6. Resolve the horizontal localization adjustment with a fixed scale
adjustment
Tap Control, Projection, Solve Localization to open the Solve
Localization wizard.
Tap Solve Rotation Only to constrain this adjustment to fix the
scale to 1.0. You can use only two points with a fixed scale
adjustment, so select 2 and CHAP as horizontal control. Tap
Solve> to open the Residuals screen.
The horizontal solution is now unique, so the misclosures to
the points not used in the solution are show. Review these
results and tap Next> to open the Results screen
The results now indicate a scale of 1.0, and the same rotation
you had before. Tap Accept to open the Adjust with Projection
wizard and preview the changes to the points.