Reference Manual Owner manual
Miscellaneous Screens 
R-447 
that is introduced when taking a shot to the prism at an 
extreme vertical angle. The 
 icon is displayed to help the 
user identify that the correct prism is selected and the Prism 
Constant is automatically set to 2 millimeters. 
•  Trimble MultiTrack (10mm): Select this option when using a 
Trimble MultiTrack prism. The 
 icon is displayed to help 
the user identify that the correct prism is selected and the 
Prism Constant is automatically set to 10 millimeters. (See 
note below.) 
Note: When using a Trimble MultiTrack prism in passive mode 
(active tracking turned off), it is important to leave the Use Target ID 
box unchecked and if the active tracking is enabled, to leave Use 
Target ID box checked since a different vertical correction is applied 
for each case. 
Use Target ID: When checked, the Target ID can be selected for the 
Smart Target. (This option is only available when using a total 
station and prism that supports target IDs.) 
•  Use For Searching: When selected, the total station will 
check the Target ID only when searching for the prism and 
then track the prism. (Once the prism is being tracked, the 
total station can potentially start tracking a different reflector 
that comes into view.) 
•  Use Always: When selected, this forces the total station to 
continuously check the Target ID; even while tracking the 
prism eliminating the possibility of the total station tracking 
a different reflector that comes into view. 
Using Active Prism: Check this option when using an active prism. 
(This option is only available when using a total station that supports 
active prisms.) 
Note: In order to perform automatic repetitions when using active 
prisms, active prisms must be set up over both the backsight and 
foresight. 