Stakeout Menu 
R-303 
Curve and Offset – Screen Two 
Station to Stake: is the desired station on the curve that 
you want to stake. 
Station Interval: is the value that is added to the Station 
to Stake after the  Next Sta  button is pressed. 
 Next Sta : advances the Station to Stake by the Station 
Interval. 
Offset: is the horizontal distance of the offset from the 
specified curve. The offset occurs on the left (while 
viewing the curve from the PC) when the L is selected or 
on the right when the R is selected. 
Note: An offset of zero would result in the specified 
curve being staked. 
V. Offset : will result in the elevations for the design points to be 
adjusted by the value entered here and will change the cut / fill 
values accordingly. Design elevations will be lower when D is 
selected, and higher when U is selected. 
Grade : specifies a slope from the specified curve to the offset that 
is being staked. When this is a non-zero value, the elevation for the 
staked points will increasingly differ from the corresponding design 
elevations on the specified curve as the Offset value increases. 
Height of Rod: is the length of the rod. 
 < Back : returns to the previous screen. 
 Solve> : accesses the third Stake Curve and Offset screen, described 
next. 
Note: A motorized total station will automatically turn toward the 
design point after tapping  Solve> , depending on the configuration of 
the Stakeout Settings screen (Page R-45). 