Reference Manual Owner manual
Stakeout Menu 
R-271 
Vert Distance: is the vertical distance from the occupy point to the 
design point. 
 ZE to Rod: is the zenith angle required to face the prism 
over the design point. 
 Circle Zero : is used to modify the circle on the total 
station so that the angle right reading will be zero when 
it is facing toward the design point, which can sometimes 
be easier than turning to an obscure angle value. When 
this button is tapped, the following actions will occur: 
1.  A new backsight circle value is computed, sent to 
the instrument and stored in the raw data 
2.  The Angle Right value is changed to zero to reflect 
the change. The instrument now needs to be 
turned horizontally to zero to face the design 
point. 
3.  To prevent errors, the backsight set up is invalidated when 
exiting the Stakeout
 dialog if this button has been used. A 
circle zeroed on a design point is meaningless once the design 
point has been staked. 
4.  The first time Circle Zero is used during a stakeout session, a 
dialog will appear to warn that the original backsight 
reference will be lost. 
Note: The Circle Zero button is not available when using a robotic 
total station. 
 < Back : returns to the first screen. 
 Stake > : accesses the third and final Stake Points screen where the 
shots to the stake point are performed. 