Reference Manual Owner manual
Survey Pro Reference Manual 
R-266 
Adjustment 
 Leveling   Adjustment. 
The Adjustment routine allows you to perform a simple arithmetic 
elevation error adjustment to an existing closed loop. You can choose 
to distribute the error equally to each setup, or apply a weighted 
adjustment proportional to the distance between each setup. You 
also have the option to adjust any side shots that were performed in 
the selected loop. 
Weigh by # of Setups: This option divides the 
computed error equally among each setup selected in the 
loop. 
Weigh by Length of Setups: This option distributes the 
error where each setup is adjusted by an error 
proportional to the length between them, so setups that 
are farther apart will carry a larger portion of the error 
adjustment than the setups that are closer together. 
Adjust Affected Sideshot Points: When checked, any 
side shots will be adjusted by the same amount as the 
setup that was occupied when the side shots were 
performed. 
Adjust Loop From Begin To End: This option includes 
every setup of the selected level loop in the error 
adjustment. 
Adjust Loop From a Specific Point To End: This option will only 
adjust the setups starting from an alternative benchmark specified in 
the Begin CBM Pt field to the end of the loop. 
Closed Loop Name: is where you select the loop to adjust from the 
dropdown list. Only closed loops are available. 
Begin CBM Pt: This item is only available when Adjust Loop From a 
Specific Point To End is selected above and allows you to select an 
alternative benchmark starting point in the loop for the adjustment. 
Any setups prior to the selected benchmark will not be adjusted. The 
description and elevation for the selected benchmark are displayed at 
the bottom of the screen. 