Key in Zone 
 Survey   Projection   Select Zone…   Key in Zone >. 
Key In Zone - Setup 
The Key In Zone Setup screen is used to pick the zone and datum 
type for the new zone, as well as set the azimuth orientation and grid 
direction for the new zone. 
Zone Type: is where you select what kind of map 
projection to use for the new zone. You can choose: 
• Transverse Mercator. 
•  Lambert 1 Parallel 
•  Lambert 2 Parallel 
•  Stereographic / Oblique Stereographic 
•  Oblique Mercator Angle 
Datum Type: is where you select what kind of datum to 
use for the new zone. You can choose: 
•  Pick from database. Choose this option to add a 
data base datum and ellipsoid to the new zone 
• Custom Molodensky. Choose this option to use a 
custom 3-parameter datum transformation, with either a 
custom ellipsoid or a data base ellipsoid. 
• Custom Similarity. Choose this option to use a 7-parameter 
datum transformation, with either a custom ellipsoid or a 
data base ellipsoid. 
Grid and Azimuth Parameters: is where you select the grid azimuth 
and the positive coordinate direction. 
• North Azimuth: is where you set a north azimuth for your new 
zone. 
• South Azimuth: is where you set a south azimuth for your new 
zone. 
• North/East Grid: is where you set the coordinates increasing 
positive in the north, east direction 