Reference Manual Owner manual
Survey Menu 
R-147 
Resection 
 Survey   Resection. 
The Resection screen allows you to compute an unknown occupied 
position by shooting two to seven known positions. 
Store Point: is the name that will be used when the new 
occupied point is stored. 
Instrument Height: is the height of the instrument 
above the ground. 
Total Resect Points to Shoot: is the number of known 
positions that will be shot, from 2 to 7. 
Shots per Resect Point: is the required number of shots 
to shoot to each foresight when Direct Only is selected in 
the next field and is the required number of sets when 
Direct and Reverse is selected in the next field. 
Sequence: is the set order when shooting each foresight. 
You can select either Direct and Reverse or Direct Only. 
 Solve⦠: accesses the Resection dialog box, described 
below, where all of the shots are performed. 