Reference Manual Owner manual
Survey Pro Reference Manual 
R-114 
Backsight Setup 
 Survey   Backsight Setup. 
The Backsight Setup screen allows you to define your backsight prior 
to performing data collection or stakeout. The screen is also 
accessible from any screen that requires a backsight. 
Note: all the information in the Backsight Setup screen is saved and 
will automatically be recalled if the job is reopened at a later time, 
but the screen must still be re-solved before you can begin surveying. 
Occupy Point: is the name of the point from the current 
job that the total station is occupying. 
HI: is the height that the total station is above the 
ground. 
HR: is the distance that the backsight prism is above the 
ground. 
: opens the Smart Target options (Page R-444). 
BS Point  / BS Direction : is the point or direction of 
the backsight where the total station is aiming. 
Fixed Backsight: should be checked when a separate 
prism is set up over the backsight. The rod height 
entered here is then used independently of the foresight 
rod height when checking the backsight by distance and 
when shooting the backsight during repetition shots. 
Backsight Circle: displays the backsight circle value, which is set 
using the  Circle…  button, described below. 
Note: The backsight circle angle is subtracted from all horizontal 
angles that are read during data collection and the resulting points 
are adjusted accordingly. This is usually only done when surveying 
in true azimuths. This value can be change from the Backsight Circle 
or Backsight Solved screens. 