Job Menu – GPS Module 
R-99 
IP Modem Settings Screen 
The IP Modem Settings screen is used to create or modify an IP 
modem configuration. (You can only configure in IP modem when 
RTK Rover is selected for the receiver.) 
IP Address of Base: is the IP address of the base. 
Port (Socket) of Base: is the socket number of the base. 
Use Advanced Settings: When checked, allows you to 
specify alternate Hayes AT commands to connect and 
disconnect. When unchecked, the default connect 
command of ate0&d0dt and disconnect command of 
ath0 will be used. 
Connection Command: is the alternate Hayes AT 
command used to connect. 
Disconnect Command: is the alternate Hayes AT 
command used to disconnect. 
General Settings 
The General Settings card is used to configure settings specific to 
each brand and model. Models which have special settings available 
are described below. 
Settings For Trimble Receivers: 
Store post process file to: is where you choose the location of the 
post processing file. Choices are: 
• Receiver memory 
• Data Collector 
Note: This setting is only available when your receiver model is 
5700, 5800, R7, R8. 