User Manual Manual

Trouble Shooting
85
Stake out to Point
101
has now begun. Watch the design
location move to the rover location, as you get closer.
Press to accept this staked location and return to the
Stake Points screen.
10.
Conventional measurements
Tap the instrument icon in the title bar and switch to
Conventional Mode
.
Go to the Surveying
card from the Job, Settings screen.
Select
Use Scale Factor
and
Prompt to Reset Scale With New
Setups
. You need to apply a scale factor to your conventional
measurements because your coordinate system is a mapping
plane. ( If you were using localization, you will generally leave
scale factor for conventional measurements at 1.0.) Tap
to open the Scale Calculator
wizard.
11.
Set up back sight.
Go to Back Sight Setup
. Occupy
OIP1
, and back sight
OIP2
and tap .
You are prompted that the scale factor for this point is
different from the current scale factor. Tap .
Use the Scale Calculator
to solve the scale factor for this
setup. A new mode record is written to raw data.
12.
Side shots and traverse.
Take a 100.0-m . View the results tab to see how
the horizontal distances are scaled.
Take a shot at
AR
= 0.0
,
ZE = 45.0000
,
SD = 1000.0
.
At the prompt, tap .
You will be prompted to reset scale since your elevation has
changed significantly.
The scale is updated and a new mode record is written to the
raw data. Subsequent shots are scaled with the new value.
13.
Using the scale factor in COGO calculations
Go to Point in Direction
from the Cogo menu.