Reference Manual Instruction Manual

74
Using the Web Server
Deleting a message definition can be done by simply
clicking on the corresponding “trash” sign in the Clear
column on the far right. This deletes the table row.
There is also a Clear All button under the table that
allows you to delete all message definitions from the
table in one click.
Click on the Configure button to save all the changes made
and then go back to the Base Setup menu
Use one of the typical applications described below to
make the generated data available to users:
Radio transmitter
Direct IP via modem
Direct IP via Ethernet
NTRIP server via modem
NTRIP server via Ethernet
RTK corrections delivered on port A, B or F
Ethernet data streaming.
Radio Transmitter
Cl
ick on Base Setup > Transmitter and define the general
parameters of the base, as explained in section General
Parameters on page 68. Then proceed with the steps
below.
Scroll down the page to display the Transmitter frame. In
the Message field, select the type of differential data the
base will generate and the radio will transmit (ATOM,
RTCM, CMR, CMR+ or DBEN). Following your selection,
ProFlex 800
RTK Corrections
Serial Port
ProFlex 800
RTK Corrections
Radio
UHF Connector
External Radio
(Internal)