Reference Manual Instruction Manual

57
Using the Web Server
authentication (e.g. SpiderNet). In that case, the
message “$GPUID,<login>,<password> will be
generated automatically and sent to the server when
clicking on Configure
Enable Connect Now to allow the receiver to establish
the connection right after you have clicked on
Configure.
At the bottom of the page, in the Differential Port pane,
select the Automatic option to let the receiver detect the
incoming differential stream automatically.
NOTE: Automatic is the recommended choice for the
Differential Port setting because in this case, you don’t
need to define the ports receiving the two possible
differential streams.
Click on the Configure button to let the Web Server load all
your new parameters to the receiver. You just have now to
define the output messages (see Defining Output
Messages on page 64).
NTRIP Client Via
Modem
The internal modem should be configured first:
Click on the Connections menu and then on the Bluetooth/
Modem sub-menu.
Set the following parameters in the Internal Modem/Device
Settings pane:
Power: Select “On”. Then choose whether the modem
should be turned on automatically or manually:
Automatic: The modem will be switched on or off
automatically when the rover is respectively turned on
or off.
Manual: The modem will be powered up only by going
through the Connections > Bluetooth/Modem page and
setting the modem to “Power On” (or using the
$PASHS,MDM,ON command).
Automatic Connection: Check this option.
Modem
RTK Corrections
ProFlex 800
NTRIP Caster
(Mobile Wireless
Communication)
Internet
IP address
or server name
(Client)