Reference Manual Instruction Manual

512
Query Command Library
Relevant Set
Command
$PASHS,ATM
See also $PASHQ,ATM
$PASHQ,ATO
SIT Site ID 4 characters
REC
Data recording:
Y: Data recording enabled
N: Data recording disabled
S: Data recording enabled but stopped
Y, N, S
MEM
Selected memory:
M: Internal memory
U: USB memory
M, U
ANH Antenna height 0.000-99.999
ANT Height measurement type (slant/vertical) SLANT, VERT
ANR Antenna reduction mode ON, OFF, ARP
ATOM ATOM message type
PVT, ATR, NAV, DAT,
EVT, RNX
PRTA
PRTB
PRTF
Labels for serial ports A, B and F ON, OFF
PRTC Label for Bluetooth ON, OFF
PRTE Label for Modem ON, OFF
PRTI Label for Ethernet ON, OFF
MEMM
MEMU
MEMR
Labels for memories M, U and R ON, OFF
I1-I9 Data streaming port ON, OFF
BAUD
If serial port used, then baud rate
If memory used, “0” if not available, else “1”
0-15 (see table
below)
Code Baud Rate
Code
Baud Rate
0 300 8 57600
1 600 9 115200
2 1200 10 230400
3 2400 11 480600
4 4800 12 921600
5 9600 13 1428571
6 19200 14 2500000
7 38400 15 5000000
Parameter Description Range