Reference Manual Instruction Manual
483
Set Command Library
TLT,INTVL: Defining the Time Interval to Acquire Tiltmeter Data
Function This command is used to define the time interval through
which the receiver will regularly ask the tiltmeter to return its
data. The command also specifies the ID of the receiver port
used to communicate with the tiltmeter.
By default, the receiver will query the tiltmeter every second
once the receiver has notified the tiltmeter, through the
$PASHS,OUT,x,TLT,ON command, to start operating.
Command Format Syntax
$PASHS,TLT,INTVL,c1,d2[*cc]
Parameters
Example
Setting query interval to 10 seconds, tiltmeter on port F:
$PASHS,TLT,INTVL,F,10*1B
Relevant Query
Command
$PASHQ,TLT
See Also $PASHS,TLT,CMD
$PASHS,TLT,INIT
$PASHS,OUT,x,TLT
Parameter Description Range Default
c1 Receiver serial port connected to the tiltmeter. A, B, F
d2 Query interval, in seconds 1-86400 1
*cc Optional checksum *00-*FF