Reference Manual Instruction Manual

421
Set Command Library
Parameters
Example
Making the falling edge active:
$PASHS,PHE,F*42
Relevant Query
Command
$PASHQ,PHE
See Also $PASHS,NME,TTT
POP: Setting Internal Update Rate for Measurements and PVT
Function This command allows you to set the updates rate used
internally in the measurements and position processing.
Command Format Syntax
$PASHS,POP,d[*cc]
Parameters
Example
Setting the update rate to 10 Hz:
$PASHS,POP,20*17
Comments
Outputting data at 20 Hz through $PASHS,NME,
$PASHS,ATM and $PASHS,RAW requires that the present
update rate stays at 20 Hz (default value).
Parameter Description Range Default
c1
Active edge code:
“R” for rising edge
“F” for falling edge
R, F R
*cc Optional checksum *00-*FF
Parameter Description Range Default
d
Internal update rate, in Hz, for measure-
ments and PVT.
10, 20 20
*cc Optional checksum *00-*FF