Item Brochure

Distance Measurement
Range with specied prisms
(Good conditions
1
) with reector sheet
5 cm x 5 cm ( 2 in x 2 in)
2"
- 1.5 m to 270 m (4.9 ft to 886 ft)
5"
- 1.5 m to 300 m (4.9 ft to 984 ft)
With single prism 6.25 cm (2.5 in)
2"
- 1.5 m to 3,000 m (4.9 ft to 9,843 ft)
5"
- 1.5 m to 5,000 m (4.9 ft to 16,404 ft)
Range Reectorless mode
2
2" Good
1
Normal
4
Difcult
5
KGC
3
350 m 250 m 200 m
(18%) (1,148 ft) (800 ft) (656 ft)
KGC 500 m 400 m 250 m
(90%) (1,640 ft) (1,312 ft) (820 ft)
5" Good Normal Difcult
KGC 280 m 250 m 200 m
(18%) (920 ft) (800 ft) (656 ft)
KGC 500 m 500 m 300 m
(90%) (1,640 ft) (1,640 ft) (984 ft)
Shortest possible range: 1.5m (4.9 ft)
Accuracy
6
(Precise mode) ISO 17123-4
- Prism: ±(2+2 ppm × D) mm
- Reectorless: ±(3+2 ppm × D) mm
Measuring interval
7
Prism Precise Normal
mode mode mode
2" 1.6 sec 0.8 sec
5" 1.5 sec 0.8 sec
Reectorless Precise Normal
mode mode mode
2" 2.1 sec 1.2 sec
5"
8
1.8 sec 1.0 sec
Least count 1 mm 10 mm
(0.002 ft) (0.02 ft)
Angle Measurement
DIN 18723 accuracy
- horizontal: 2"/0.6 mgon
- vertical: 5"/1.5 mgon
Reading system: Absolute encoder
Circle diameter: 62 mm (2.4 in)
Horizontal/Vertical angle
- 2": Diametrical/Diametrical
- 5": Diametrical/Single
Minimum increment
- Degree: 1/5/10”
- Gon: 0.2/1/2 mgon
- MIL6400: 0.005/0.02/0.05 mil
Telescope
Tube length: 125 mm (4.9 in)
Image: Erect
Magnication:
30× (18×/36× with optional eyepieces)
2" Effective diameter of objective:
40 mm (1.6 in)
2" EDM diameter: 45 mm (1.8 in)
5" Effective diameter of objective:
45 mm (1.8 in)
5" EDM diameter: 50 mm (2.0 in)
Field of view: 1°20’
Resolving power: 3"
Minimum focusing distance: 1.5 m (4.9 ft)
Laser Pointer: Coaxial Red Light
Tilte Sensor
Type: Dual-axis
Method: Liquid-electric detection
Compensation range: ±3.5'
Communications
Communication ports:
- 1 x serial (RS-232C)
- 1 USB
Wireless communications:
- integrated Bluetooth
Power
Internal Li–ion battery (x2)
Output voltage: 3.8 V DC
Operating time
9
2"
- approx. 19 hours (continuous distance/
angle measurement)
- approx. 57 hours (distance/angle
measurement every 30 seconds)
- approx. 62 hours (continuous angle
measurement)
5"
- approx. 10 hours (continuous distance/
angle measurement)
- approx. 26 hours (distance/angle
measurement every 30 seconds)
- approx. 31 hours (continuous angle
measurement)
Charging time
Full charge: 4 hours
General Specications
Level vials
Sensitivity of Circular level vial: 10'/2 mm
Optical plummet
Image: Erect
Magnication: 3×
Field of view: 5°
Focusing range: 0.5 m (1.6 ft) to ∞
Display face 1: backlit, graphic
LCD (128×64 pixel)
Display face 2 (2" only): backlit, graphic
LCD (128×64 pixel)
Laser plummet (optional): 4 levels
Point memory: 50,000 records
Dimensions (W x D x H):
149 mm x 145 mm x 306 mm
(5.8 in x 5.7 in x 12.0 in)
Weight (approx.)
2" Main unit (without battery): 3.8 kg (8.4 lb)
5" Main unit (without battery): 3.7 kg (8.1 lb)
Battery: 0.1 kg (0.2 lb)
Carrying case: 2.3 kg (5.1 lb)
Environmental
Operating temperature range:
–20 °C to +50 °C (–4 °F to +122 °F)
FOCUS 6W
+
: –30 °C to +50 °C
(–22 °F to +122 °F)
Storage temperature range:
–25 °C to +60 °C (13 °F to +140 °F)
FOCUS 6W
+
: –30 °C to +60 °C
(–22 °F to +140 °F)
Atmospheric correction
Temperature range:
40 °C to +60 °C (–40 °F to +140 °F)
Barometric pressure:
400 mmHg to 999 mmHg/533 hPa to
1,332 hPa/15.8 inHg to 39.3 inHg
Dust and water protection: IP66
Certication
Class B Part 15 FCC certication,
CE Mark approval.
C-Tick.
Laser safety IEC60825-1 Ed. 2.0 : 2007
2" Reectorless / Laser Pointer: Class 3R laser
2" Prism mode: Class 1 laser
5" Reectorless : Class 1 laser
5" Laser Pointer: Class 2 laser
Laser Plummet (optional): Class 2 laser
Bluetooth type approvals are country specic.
(1) Good conditions (good visibility, overcast, twilight, underground,
low ambient light).
(2) Measuring distance may vary depending on targets and
measuring conditions.
(3) Kodak Gray Card, Catalog number E1527795
(4) Normal conditions (normal visibility, object in the shadow,
moderate ambient light).
(5) Difcult conditions (haze, object in direct sunlight,
high ambient light).
(6) ±(3+3 ppm × D) mm –20 °C to –10 °C, +40 °C to +50 °C
(–4 °F to +14 °F, +104 °F to +122 °F)
(7) Measuring time may vary depending on measuring distance
and conditions. For the initial measurement, it may take a few
more seconds.
(8) Measured to KGC 90% at 20 m (65 ft)
(9) Battery life specication at 25 °C (77 °F). Operation time may be
shorter in low temperatures or if the battery is not new.
FOCUS 6
+
Technical Specications
©2016 Trimble Navigation Limited. All rights reserved. Spectra Precision is a Division of Trimble Navigation Limited. Spectra Precision and the Spectra Precision logo are trademarks of Trimble Navigation
Limited or its subsidiaries. All other trademarks are the property of their respective owners. (2016/09)
Contact Information:
AMERICAS
Spectra Precision Division
10368 Westmoor Drive
Westminster, CO 80021, USA
+1-720-587-4700 Phone
888-477-7516 (Toll Free in USA)
EUROPE, MIDDLE EAST AND AFRICA
Spectra Precision Division
Rue Thomas Edison
ZAC de la Fleuriaye - CS 60433
44474 Carquefou (Nantes), France
+33 (0)2 28 09 38 00 Phone
ASIA-PACIFIC
Spectra Precision Division
80 Marine Parade Road
#22-06, Parkway Parade
Singapore 449269, Singapore
+65-6348-2212 Phone
www.spectraprecision.com