71
left of the measuring beam, they will see a red flashing light; if
they are to the right, they will see a green flashing light.
B TIP – You can use the Tracklight for clearing sight lines
and as an aid to find prisms in the dark or unfavorable
sighting conditions.
C CAUTION - Do not use the laser pointer as an aid when
searching for prisms, the reflected light can dazzle your
eyes. The reflected light will not damage your eyes, but
might be uncomfortable.
Servo Technology The instrument is equipped with servo controlled motors to
position the instrument and focus the telescope.
Due to the high speed position servo and the SurePoint
technology used in the instrument it is important to use a high
quality tripod and tribrach. It is also important to set up the
tripod in a position for best stability. If the setup, tripod and/or
tribrach is/are unstable the instrument servos might oscillate