4. Check the alignment of the laser spot and the cross-hairs.
Throughout the adjustment procedure, keep the telescope
pointing to the adjustment target. The adjusting screws are
of a high tension because they are self locking. The screws
tighten automatically after you adjust them.
5. Refit the plugs in the adjustment holes. Make sure that the
plugs are correctly fitted for proper sealing against the
cover.
C CAUTION - To keep out moisture and dust, make sure that
the plugs are correctly fitted in the adjustment ports.
Measuring the
Instrument Height
There are two measurement marks on the side of the
instrument. The true height mark corresponds to the trunnion
axis of the instrument. The bottom notch height mark is
0.158 m (0.518 ft.) below the true height mark. Measure the
bottom notch height mark to the top ridge of the mark.
Clockwise = Left