Product Manual

Table Of Contents
42
If you select Continue:
3. Press A to scroll to one of the following:
New observation. Then press C to continue the
HA/VA collimation test.
Change face. Then press C to change between
face 1 and 2.
Cancel. Then press C to return to the Adjustments
menu.
If you select New observation:
a. Aim accurately in face 2 towards a point near the
horizon at max. ±5 grads (± 4.5 degrees) to the
horizontal and at a minimum distance of 100 m
(328 ft.).
b. Press A to scroll to New observation. Press C
to measure and record angles
c. Re sight the instrument at the same point and press
the enter key again. Repeat this process for a
minimum of five sightings in face 2.
d. Press A to scroll to Change face. Then press C
to change to face 1.
e. Aim accurately towards the same point as that used in
face 2.
Aim on target
New observation
Change face
>>
Face-1 obs: 0
New observation
Change face
Face-2 obs: 0
>>
C