Product Manual

37
All parameters are reset to defaults except for ephemeris,
almanac, position and time data. SBAS ephemeris data
are however cleared. Then default_config.cmd is run if
present.
RESET IN PROGRESS” is displayed throughout the
sequence (which may take a few minutes). At the end of
the sequence, hold the escape button depressed for a few
seconds to return to the General Status screen
3. Upgrade firmware?: Allows you to upgrade the firmware of
your receiver.
When Spectra Precision releases a new firmware version,
copy the corresponding *.tar file to a USB key and
connect that key to the receiver via the USB connector on
the receiver front panel.
Once done, when you select the Upgrade firmware?
function, the screen will show the firmware version you
can now install. Press OK if you agree and let the receiver
complete the installation. For more information on
firmware upgrades, see page 43 or web page Receiver >
Configuration > Firmware Upgrade in the Web Server.
4. Execute script? Allows you to have the receiver executing
all the proprietary commands listed in a *.cmd file stored
on the connected USB key.
5. Anti-Theft: This option allows you to enable (ON) or disable
(OFF) the anti-theft protection. You need to enter the
correct password if you want to remove the anti-theft
protection.
6. Startup Protection: This option is displayed only if the
startup protection has been activated beforehand,
meaning a password will be requested if someone wishes
to use the receiver next time it is turned on.
When you view this screen, you are prompted to remove
the startup protection (“Remove” displayed in second
line). Just press OK, enter the password and press OK
again to remove the startup protection.