Product Manual

92
[1]: SP File Manager toolbar. This toolbar consists of the
following items:
Port and baud rate scroll-down lists: Let you choose which
serial port is used on computer side for the connection
with the receiver (baud rate only makes sense when an
RS232 serial line is used). Use 115200 Bd to
communicate with SP90m.
Connect / Refresh button: Connect allows you to activate
the connection between the computer and the receiver via
the chosen serial line.
When the connection is established, the button is
changed into Refresh, which allows you to update the
content of the two SP File Manager panes ([2] and [3]
described below)
Disconnect button: Allows you to deactivate the connection
currently established between the computer and the
receiver.
Copy button: Copies the file(s) selected in pane [3] to
pane [2]. In pane [2], you have to open the folder where
to copy to before clicking on the Copy button.
NOTE: Copied files have different creation dates and
times compared to those of their respective original files.
The new dates and times are those corresponding to when
the files were copied.
Delete button: Deletes the files currently selected in pane
[2] or [3].
[2]: Pane showing the content of the currently open folder on
computer side.
[3]: Pane showing the content of the currently open folder on
receiver side. The receiver’s root folder contains two to four
sub-folders:
Internal memory: Lists all G-files recorded by the receiver
in its internal memory
Log files: Contains log files (one per day). Each log file
lists all the actions performed by the receiver in one day.
SD Card, if one is currently inserted in the receiver.
USB key, if one is currently connected to the receiver.
To open a folder, double-click on it. To go back to the parent
folder, click on .
[4]: Pane showing copy/delete operations in progress, and all
those completed since the connection with the receiver was
established. This pane is cleared at the beginning of each
new working session of SP File Manager.