Product Manual
22
English
– RTK tab: See the two tables below for the required settings.
– For a base, as recalled in these two tables, choose the format
of corrections (ATOM, RTCM, CMR)
– Tap to complete the receiver configuration.
1) SP60 Standalone Rover
NOTE: To choose a datum other than ITRF08 after having selected
“RTX”, go back to the Receiver tab and tap 14 Parameter Datum.
Choose a different datum from the Datum Name scroll-down list. To
enter a custom datum, select “<New>” from the same list and enter
the datum parameters in the fields underneath.
2) SP60 Base-Rover System
* Provided the data collector modem supports this mode.
SP60 Used As:: Set “Device” to: Set “Network” to: Other Settings:
Network Rover
“Data Collector
Internet”
1) “TCP/IP Direct”
2) “UDP/IP Direct”
3) “NTRIP”
1) Network parameters,
2) Modem APN and PIN
L-Band Rover
(RTX)
“LBand” (RTX)
Datum on Receiver tab
(see NOTE below)
Base/Rover
System Uses:
Receiver
Function
Set “Device” to:
Set “Network”
to:
Other Settings:
Long-range
Bluetooth: Set
the base first!
Base “Receiver Bluetooth” (None)
1) Keep baud rate
at 115200
2) Message type
Rover “Receiver Bluetooth” (None)
1) Keep baud rate
at 115200
2) Scan for base
Bluetooth device
and pair with it.
Radio link
Base
1) “Internal XDL”
2) ‘”Pacific Crest PDL”
3) “ADL Vantage (Pro)”
(None)
1) Radio settings
2) Baud rate
3) Message type
Rover “Internal XDL” (None) Radio settings
CSD link*
Rover “Data Collector Phone” “Direct Dial”
1) Define a base
name
2) Enter its phone
number
(Base: Typically not an SP60)