1. Select the sensor ID, click “Enable” and set the alarm type, alarm holding time and sensor
name.
2. Set alarm trigger options. The setup steps are the same as temperature screening settings.
Please refer to temperature screening settings chapter for details.
3. Click “Save” button to save the settings.
4. Set the schedule of the sensor alarm. The setup steps of the schedule are the same as the
schedule recording setup. (See Schedule Recording).
Click “Apply settings to” to quickly apply the settings to the other alarm input.
6.3.7 Alarm Out
Go to ConfigAlarmAlarm Out.
Alarm Out ID: Select the alarm out ID.
Alarm Out Mode: Alarm linkage, manual operation, day/night switch linkage and timing are
optional.
Alarm Linkage: Having selected this mode, select alarm out name, alarm holding time at the
“Alarm Holding Time” pull down list box and alarm type.
Manual Operation: Having selected this mode, select the alarm type and click “Open” to
trigger the alarm out immediately; click “Close” to stop alarm.