User Manual
24
The depression angle of the camera shall range from 10° to 15°.
If the camera is installed on the side of the road, the pan angle of the camera shall range from 0° to 20°.
If the camera is installed right above the middle of the road, the pan angle of the camera shall range from -10° to 10°.
Entrance & Exit Monitoring
The installation height (H) shall range from 4.2ft to 5ft.
The distance D (between the location of the camera installation and the captured area) shall range from 8.2ft to 10ft.
The distance of the captured area (L) shall be from 5ft to 6.5ft.
The depression angle of the camera shall range from 0° to 5°.
The pan angle of the camera shall range from 5° to 20°.
The tilt angle of the license plate
After the camera is installed, you can log in the web client and view whether the license plate tilts in the video. The tilt angle shall range from -5° to 5°.
If the captured license plate doesn’t meet the above requirement, you can adjust the pan angle of the camera to correct it.
<40M
PH