3.9 Alarm
ALARM SETUP
NO PRI FUN IN OUT HLD LATCH
01 1 001 NO ON 03 OFF
02 1 --- OFF OFF 03 OFF
03 1 --- OFF OFF 03 OFF
04 1 --- OFF OFF 03 OFF
DWELL : 03
ALARM OUT SETUP
SAVE AND EXIT(ESC TO CANCEL)
NO : alarm input number
PRI(Priority) : The lower number has higher priority. (0 ~ 4)
FUN(Function) : Stored function number to be called by alarm.
IN : NO/NC – normally open/closed, OFF – ignore
OUT : ON – 5VTTL output, OFF – no output
HLD(Hold) : Alarm will be held for programmed time. (03 to 99 seconds)
LATCH : ON – Alarm message will remain on the screen even though alarm input
is deactivated.
OFF – Alarm message will disappear from the screen after programmed
hold time when alarm input is deactivated.
DWELL : means the dwell time during multiple alarms, 03 to 99 seconds.
ALARM OUT SETUP
OUT : ALARM
EXIT(ESC TO EXIT)
ALARM: alarm output is operated during an alarm operation or by the short key of our
keyboard.
1 ~ 5 MIN(minute): alarm output is operated during this setting time only by the function run
of the dome menu or the short key of our keyboard.
NOTE: This 1 ~ 5 MIN setting is not operated by an alarm.
3.10 Area Title
Enter a specific name on programmed angle between START and END. For the screen below,
when the camera points at an angle between 124.3
(PAN), 30.7 (TILT) to 359.5 (PAN), 45.4
(TILT), ABC will be displayed on the screen.
AREA TITLE SETUP
NUMBER : 01
TITLE : ABC
START ANGLE : 124.3 30.7
END ANGLE : 359.5 45.4
SWAP : OFF
SAVE AND EXIT(ESC TO CANCEL)
NUMBER : 01 ~ 16