Home Security System User Manual
37X Speed Dome Camera  36/50
 Alarm Input Setup 
ALARM INPUT SETUP
------------------------
 ALARM NO. 1
 TYPE N.OPEN
 ACTION NOT USED
 HOLD TIME ENDLESS
 POST ACTION HOME
 BACK
 EXIT
Defines Alarm Function. When an alarm is receive, an 
input signal to the camera triggers the user-defined action 
programmed for the alarm. 
z Alarm No  [1~3] 
Selects a sensor number to set up. 
z Type  [Normal OPEN/Normal CLOSE] 
Selects sensor operation type. 
z Action  [NOT 
USED/PRESET/PATTERN/SWING/GROUP] 
Selects an action to run when a sensor 
signal is input. 
z Hold Time  [ENDLESS / 1~59 SEC. / 1~180 MIN.] 
Sets the time period for the action which is 
run by external sensor activation. After the 
time period passes, the action pre-defined 
in  “Post Action” runs sequentially in 
succession to the action by external sensor 
activation. If this option is set to 
“ENDLESS”,  “Post Action” does not 
activate. 
z Post Action
[HOME/PRESET/PATTERN/SWING/GROUP
/PREV ACTION] 
Selects the action that a camera will run 
after the time period in“HOLD TIME” 
passes. If Post Action is set to “PREV. 
ACTION”, the camera runs the previous 
action which it ran most recently. 
OSD MENU 4