DVR User Manual
7
Dome Camera Control 
Dome Camera Connection & Settings: 
•  See section Pin Definition of Alarm I/O & RS-485, and Audio In
 for RS-485 port pin definition. 
•  Connect the R+, R- terminals on the dome camera to the D+, D- terminals on the RS-485 port 
by RS-485 cable respectively. 
•  To set up dome camera’s protocol and ID, press MENU to access the OSD main menu or 
change the protocol and ID by using SpecoRemote, and select <Camera Setup>. The available 
protocols include <Speco>, <DSCP>, <AD422>, <Pelco D>, <Pelco P>, <Fastrax 2>, <JVC>, 
<Panasonic_C>, and <Panasonic_N>. The default is <None>. Note that ID number must 
match the ID address defined by the dome camera. 
•  To configure the RS-485 parameters, select <System Setup> from OSD main menu or through 
SpecoRemote, and then select <RS485 Setup>. The default RS-485 settings are 9600 Baud, 8 
Data Bits, 1 Stop Bit and No Parity. 