User guide

SC3/15 PROBLEMS: - Refer to this chart and the SC3/15 PROBLEM NOTES (next
page) to help diagnose potential problems based on the
SC3/15 readings
CASE BATTERY METER PANEL METER CHARGE
LIGHT
OTHER SC3/15
NOTE
(Next page)
1
No Volts (9 on meter) Day/Night See Note 1
(next page)
2
No Volts (9 on meter) Night only See Note 2
3
Voltage 9-12 No amps OFF Day time See Note 3
4
Voltage 14.7 - 15.0 See Note 4
5
Voltage meter less than
actual battery voltage
See Note 5
6
Voltage meter higher
than actual battery
voltage
See Note 6
7
Voltage reading erratic See Note 7
8
No amps ON Day time See Note 8
9
Turns OFF
(too soon)
Day time See Note 9
10
ON - at night See Note 10
11
Panel meter
moving rapidly
Charge light
may also be
going on and
off rapidly
See Note 11
12
Current meter less
than expected
panel current
See Note 12
13
Changing to
ON or OFF
Front fuse
being
touched or
taken out
See Note 13
14
SC3/15
buzzing
See Note 14
15
SC3/15
hot