Installation & Assembly
HANDLE AND DIAL CAP REMOVAL
9
3/32"
The Handle and Dial Cap must be removed to adjust the Temperature Limit Stop. Remove the Handle Screw (1),
then slide the Handle (2) off. Remove the Dial Cap Screw (3) followed by sliding off the Dial Cap (4).
If you are performing a
Standard Installation,
please proceed to
Step 10.
If you are performing a
Back-to-Back
Installation, please
proceed to Step 14.
TEMPERATURE LIMIT ADJUSTMENT
10
Remove Handle and Dial Cap as shown in STEP 9.
Important- Check each valve installation with a
thermometer to make sure the maximum hot water
temperature is set to the recommended setting of 110° F
maximum. To lower the limit of the maximum hot water
temperature the valve delivers, adjust the valve’s
temperature limit stop (TLS) plate.
1) Slip the retaining O-ring and the TLS plates towards
the end of the spindle.
(2) With the water supplies on, rotate the valve spindle
clockwise to the maximum desired hot water
temperature.
(3) Position the bottom TLS plate so it contacts the upper
side of the bonnet post and therefore restricts the
clockwise rotation of the spindle.
(4) The top TLS plate should be adjusted so that it comes
in contact with the lower side of the bonnet post when
the valve is rotated counter-clockwise to the “OFF”
position.
(5) Slip the retaining O-ring back into the groove of the
spindle to hold the TLS plates in place.
O-RING
HANDLE AND DIAL CAP INSTALLATION
11
3/32"
Slide on the Dial Cap (1) onto the Bonnet. Tighten in place with the Dial Cap Screw (2). Slide the Handle (3)
onto the Valve post. Then tighten with Handle Screw (1).
12
Turn on water supplies. Turn on Valve to the
"WARM" position and flush for 1 minute.
13
OPTION: If your unit comes with shower head, apply Thread Seal Tape to threads of Shower Arm (1). Thread
Shower Head (2) onto Shower Arm (1) and tighten with Adjustable Wrench. Check all connections for leaks.
NOTE: Shower head not
included with all models.
Shown for reference only.
14 BACK-TO-BACK INSTALLATION
Your Shower Valve has the ability to be mounted back-to-back with another Valve in a shared space. This means the HOT
and COLD inlets may be reversed. Please see the following steps to adapt your valve for back-to-back mounting or
reversed inlet supplies.
If the HOT and COLD water supplies are reversed (HOT on right and COLD on left), disassemble Valve Cartridge as
outlined in STEP 15.
Rotate Valve Cartridge
❺
180˚ and reinstall into Valve Body. The “H” marking on the blue Valve
Cartridge cover should now be on the right hand side. Reinstall Bonnet
❹
and four (4) Bonnet Screws
❸
, making sure
the Large Bonnet O-Ring is in place within the Valve Body. Reinstall TLS Plates
❷
and Spindle O-Ring
❶
.
Tighten
securely. Take care to not over tighten connection or damage may occur.
NOTE: Never install the valve body upside down!
Reverse
Installation
COLD
COLD
COLD
COLD
COLD
HOT
HOT
HOT
HOT
HOT
Normal Installation
(shown without Bonnet)
H
Reverse Installation
(shown without Bonnet)
C
Normal Installation
(changes not required)
Please proceed to
Step 10.
BACK TO BACK INSTALLATION
15
Remove spindle O-ring ❶, TLS plates ❷, and four (4) Bonnet Screws ❸. Then remove Bonnet ❹ and Cartridge
Assembly ❺ from valve body.