Installation
2"
MIN. TO LEDGE
51mm
2"
MIN. TO WALL
51mm
LAVATORY ROUGH-IN
32mm
1
1
4
"
MIN
32mm
1
1
4
"
MIN
2
1
4
"
57mm
1
1
16
"
27mm
4
1
2
"
115mm
AIR TUBE
30"
SOAP TUBE
12"
5
5
8
"
143mm
15.00°
3
13
16
"
97mm
SFS-8000 ROUGH-IN DIAGRAM
SPEAKMAN
®
ALL DIMENSIONS ARE IN INCHES (MILLIMETERS) UNLESS
OTHERWISE SPECIFIED. DIMENSIONS SUBJECT TO
CHANGE WITHOUT NOTICE.
2"
MIN. TO LEDGE
51mm
2"
MIN. TO WALL
51mm
LAVATORY ROUGH-IN
32mm
1
1
4
"
MIN
32mm
1
1
4
"
MIN
6
5
16
"
161mm
3
7
16
"
88mm
4
3
8
"
112mm
2"
MAX
2"
51mm
SFS-9000 ROUGH-IN DIAGRAM
SPEAKMAN
®
ALL DIMENSIONS ARE IN INCHES (MILLIMETERS) UNLESS
OTHERWISE SPECIFIED. DIMENSIONS SUBJECT TO
CHANGE WITHOUT NOTICE.