Installation
Table Of Contents
13
When choosing your Solenoid Mounting Location, verify that all electrical connections are within reach. Place
the Solenoid Assembly against the desired mounting surface while ensuring adequate clearance for servicing
of all connections. Solenoid Assembly should be mounted so the inlet and outlet ports are aligned vertically.
Mark location of Solenoid Assembly on the mounting surface using a pencil.
14
Remove Mounting Bracket (1) from Solenoid Assembly. Using the previously marked location on mounting
surface, align Mounting Bracket (1) horizontally to approximate position and mark the mounting locations with a
pencil. If mounting on drywall and not to stud, use the appropriate anchors and fasteners for application.
Recommend screw in easy anchor or equal for drywall.
IMPORTANT NOTE
Verify that all hoses are free from bends or kinks.
15
After securing the Bracket to the mounting surface, align and slide Solenoid Assembly over
Mounting Bracket.
16
If mixed water is desired, a Hot and Cold water
mixing device (not included) is needed. Ensure
the water supplies are turned "OFF". Make
connections between the Shut Off Valve and the
inlet of the Solenoid. The inlet thread of the
Solenoid is 9/16”-24 UNF and will accept a
3/8” Compression Fitting. Wrench Tighten.
(Supply Stops and Inlet Hoses are not included).
Accepts a 3/8”
Compression
Fitting
SUPPLY STOPS NOT INCLUDED
17
Assemble Solenoid "INLET" Supply Hose (1) to the "INLET"
connection (2) of Solenoid. Wrench tighten.
DRY CONNECTION ONLY.
DO NOT USE ANY SEALANT
ON THIS CONNECTION
IMPORTANT
Flush Water Supply Lines
into a Bucket for 1
Minute prior to making
connection.
WATER SUPPLY LINE
18 FOR A/C POWER
Verify that no batteries are present within the battery enclosure (1). Connect the A/C Adapter to the Solenoid
Body (2). Plug the A/C Adapter into the wall outlet. The A/C light (3) should illuminate.
19 FOR BATTERY POWER
Access the interior Battery Enclosure by pressing down on the tab to release the tray holding the batteries (1).
Pull out Battery Tray (2). Insert or replace the batteries with six (6) new standard 1.5v AA batteries. Ensure the
position of the new batteries are aligned to the plus (+) and minus (-) symbols within the battery holder.
BATTERIES NOT INCLUDED
20
Reinstall the Battery Tray (1). Make sure to press
the indicated location until the battery door is
fully seated and locks into position (2).
21
Make electrical connections from the Sensor Eye to the Solenoid Assembly. Connect the Blue Male Ended Wire
to the Blue Female Connection. Connect the Green Male Ended Wire to the Green Female Connection. To
further aid proper alignment, there are white alignment lines on the connector ends. These alignment lines
should face forward when properly installed.
GREEN
BLUE
22
Turn "ON" water supplies and inspect for leaks
and proper operation of Sensor Faucet.
SUPPLY STOPS NOT INCLUDED