Position Mounting Plate (1) over Faucet Inlet Pipe
as shown below. Secure to the Horizontal Braces
with the four Mounting Screws (2) included. Install
Mounting Nut (3) and Hand tighten until it
contacts the Mounting Plate (1).
• See Detail View. Wrench tighten Front
Mounting Nut (A) and Rear Mounting Nut (B) as
to make firm contact with the Mounting Plate (1).
Thread locker is recommended.
BA
6
Route the included Wire Chase (1) as shown
below. Ensure adequate length is present on both
ends so it can extend beyond the finished wall
surface. Place Protective Sleeve (2) into the Faucet
Inlet Pipe.
7
Position back side of finished wall material
against the Protective Sleeve (1) and press with
moderate pressure. This should leave an
indentation mark to indicate where a 1-1/2” hole
will need to be drilled in the finished wall
material. Repeat process for lower hole position.
1-1/2” Hole Saw
Ø 1-1/2”
UPPER
Ø 1-1/2”
LOWER
8
Ensure Protective Sleeve is placed into Faucet Inlet
Pipe. Position Finished Wall Material against
vertical studs, while verifying that the Wire Chase
(1) is pulled through both the upper and lower
drilled holes.
9
Once finished wall installation is complete, remove the Protective Sleeve from the Faucet Inlet Pipe. Install the
Faucet Mounting Sleeve (1) into the Faucet Inlet Pipe (2) as shown below. Secure into position with the two
included Mounting Screws (3).
10
NOTE: You may need to pull on Sensor Wire from the lower exit hole in wall
to remove excess slack in wire present at the upper location.
Securely attach the Sensor Wire (A) to the upper
Wire Chase end (B). Pull lower Wire Chase end
(C) to feed the Sensor Wire to the lower exit hole
in wall. Ensure adequate Sensor Wire length is
outside the lower exit hole in wall to make
appropriate connections to the Solenoid.
• Install Spout Assembly (1) to the Faucet
Mounting Sleeve (2).
• Secure Spout Assembly (1) into position by
tightening the Hex Screw (3). Slide Escutcheon
Ring (4) into position.
B
A
C
11
Place Lower Escutcheon Ring (1) over lower hole
in wall, being sure to orient the Sensor Wire (2)
so that it exits through the cut out in the Lower
Escutcheon Ring (1). Thread Solenoid Outlet Pipe
(3) into Lower ½” Female to Female Connecter.
Wrench Tighten into position.
EXIT CUT
OUT
12
NOTE: If mounting Solenoid Assembly
remotely, follow Steps 13-15.
The Solenoid Assembly (1) can either be mounted
directly to the Solenoid Outlet Pipe (2) (A), or via
hose (not included) (B) if a different Solenoid
Assembly mounting position is desired.