Installation
Table Of Contents
INSTRUCTIONS FOR MODELS
92-SF-1000-01
For additional assistance or service please contact:
SPEAKMAN
®
800-537-2107
customerservice@speakman.com
www.speakman.com
SF-1000
SF-2000
TOOLS AND SUPPLIES
Adjustable
Wrench
Thread Seal
Tape
Aerator
Wrench
(included)
Phillips
Screwdriver
Safety
Glasses
Hex Key
Wrench
(included)
Level
Drill
Phillips
Drive Bit
Measuring
Tape
Flat Tip
Screwdriver
1-1/2” Hole Saw
Warranty information can be found at:
www.speakman.com
WARRANTY
Your new Speakman Product is designed for years of
trouble-free performance. Keep it looking new by
cleaning it periodically with a soft cloth. The use of harsh
chemicals and abrasives on any of the Speakman custom
finish products may damage the finish and void the
product warranty. Please be sure to only use approved
cleaners. Please contact Speakman for any clarification
of acceptable cleaners.
MAINTENANCE
Cover your drain to prevent loss of parts. Be sure to
wear eye protection while cutting pipe.
SAFETY TIPS
IMPORTANT
• Be sure to read instructions thoroughly before
beginning installation.
• Do not over-tighten any connections or damage
may occur.
• This installation manual covers several models.
While you models may look different, it will install
in the same manner.
• This faucet has an operating range of 20-80 psi.
1
Determine the desired mounting location of the
Sensor Faucet and Solenoid Box. Mark
appropriate locations on the vertical studs of
the wall. Draw a level line across the two (2)
Vertical Studs as shown. The distance between
the Sensor Faucet and Solenoid box must not
exceed 36”.
NOTE: Steps 1-8 must be completed
prior to finish wall installation.
2
Cut three (3) 2”x 4” Horizontal Braces to fit
between the Vertical Studs. The two (2) Upper
Braces shall each be installed 1-1/2” from the
centerline of the desired Sensor Faucet location.
The Lower Brace shall be installed 2” above the
centerline of the desired Solenoid location.
Secure Horizontal Braces to Vertical Studs.
(mounting hardware not included).
IMPORTANT: All Horizontal Braces MUST be set back
½” from the front surface of the Vertical Studs.
3
Install rough plumbing as shown below. Secure rough plumbing to Horizontal Bracing using Pipe Straps. Apply
Thread Seal Tape on all connections. (Rough Plumbing, Pipe Straps, and Mounting Hardware not included).
½” NPT 90˚ FEMALE ELBOW
½” NPT 90˚ FEMALE ELBOW
½” PIPE - LENGTH DETERMINED
BY ROUGH IN LOCATION
½” NPT FEMALE TO FEMALE
CONNECTOR
0” TO 1/4” FROM FINISHED
WALL SURFACE
½” PIPE - LENGTH DETERMINED
BY ROUGH IN LOCATION
A
PIPE STRAP
PIPE STRAP
IMPORTANT:
The front surface of the
Lower ½” NPT Female to
Female Connecter MUST be
flush to, or not protrude
more than ¼” from the
finished wall surface when
installation is complete.
Adjust the length of the
Lower Horizontal ½” pipe
(A) accordingly to
accomplish this.
4
Thread Faucet Inlet Pipe (1) into Upper ½” NPT
Female Elbow. Wrench tighten into position
using an Adjustable Wrench on the Flats of the
Faucet Inlet Pipe. Install and Hand thread
Mounting Nut (2) to the base of Faucet Inlet Pipe
(1).