Remove the 2 screws on the clamp. After
removing, pull up the Sensor Module from the
central shank (do not damage the O-Rings and
the wire connectors).
Reassemble new Module with care not to cut
wires through the big holes into the Base, then
insert the clamp with the Sensor over the shank.
Tighten the 2 screws on clamp, making sure that
the sensor sits on the flat of shank and touches
the bottom of base. Grease the 2 O-Rings or
change them if they are damaged. Take care
when inserting Faucet Spout over the Sensor O-
Ring and tighten the screw that was removed in
the back.
REPLACEMENT OF BATTERIES
To replace the batteries (if the unit purchased is
a battery powered unit) first start by unscrewing
the screw that is on the power module.
With the cover of the power module removed,
remove the dead batteries and replace them with
new batteries (ensure that the position of the
new batteries matches the marks + and - on the
cover). Replace the cover on Power Module.