Installation
92-2840-R2
5of 18
Install 3/8”compression fitting hoses to the
UCM (under counter mixing valve). The hot and
cold sides are marked H and C. Hand tighten
connections and then slightly tighten with an
adjustable wrench.
DRY CONNECTION ONLY.
NOTE: During winter month it may be
necessary to reverse Hot and Cold connections
to obtain warmer temperature range of water.
After connecting to supply lines, turn on the
water and activate the faucet with your hands,
checking for leaks. Adjust water temperature by
rotating the screw on the UCM to your required
temperature.
REPLACEMENT OF SENSOR MODULE
If the Faucet is mounted onto Deck, first take it
out with proper care to not damage the
connectors and the wires. Take out the Gasket
from under Base of Faucet. Take the screw
completely out of the back of faucet.
After screw has been removed from the unit,
pull up faucet body top. There are 2 O-Rings on
the shank and one around the lenses of Sensor
Module that should be replaced if damaged.